6. Operation
Power On/Off
Once the inverter has been properly installed, press the power switch to turn on the unit. The
unit will work automatically in line mode or inverter mode according to input utility power's
status. When press the power switch again, the unit will be turned off.
LED Indicators & Audible Alarms
There are three indicators (Green/Red/Yellow) in the front panel of the unit.
Status
Indicator
Alarm
Line
mode
Battery charging at
power on.
Green LED flashing every
2 sec.
Off
Battery fully charged
at power on.
Green LED lighting
Off
Battery charging at
power off.
Green LED flashing every
5 sec.
Off
Battery fully charged
at power off.
Green LED flashing every
11 sec.
Off
Battery
mode
Battery weak
Yellow LED flashing every
2 sec.
Sounding every 1 sec.
None weak-battery
Yellow LED lighting
Off
Shutdown mode
Yellow LED flashing every
5 sec.
Off
Fault mode.
Red LED lighting
Continuously sounding for
30 min. and then alarm
off.
The unit is overload.
Red LED flashing for 0.5
sec every sec.
Sounding every 0.5 sec.
The unit is over charged.
Red LED flashing every 4
sec.
Continuously sounding for
30 min. and then alarm
off.
LCD Display & Audible Alarm
Status
LCD Display
Alarm
Line
mode
Battery charging at
power on.
and
flashing every 2 sec.
Off
Battery fully charged
at power on.
and
lighting.
Off
Battery charging at
power off.
and
flashing every 5 sec.
Off
Battery fully charged
at power off.
and
Off
flashing every 11 sec.
Battery
mode
Battery weak
and
will flash every 2
second.
Sounding every 1 sec.
None weak-battery
Off
Fault mode
Fault code will be
displayed.
Short fault: F0
Overload fault: F1
Battery bad: F2
High output voltage: F3
Main Relay Stick:F4
Fan fault: F5
Continuously sounding for
30 min. and then alarm
off.
The unit is overload.
The mark
will
flash every second.
Sounding every 0.5 sec.
Load level indicator:
Battery capacity indicator:
Display
Load Level
Display
Battery Capacity
75%~100%
battery voltage ≥ 12.5V (25V)
50%~75%
12.5V (25V)> battery voltage ≥
11.5V (23V)
25%~50%
11.5V (23V)> battery voltage ≥
11.0V (22V)
0%~25%
battery voltage < 11.0V (22V)
Operation Mode Selector
a). “UPS”: setting for conventional electrical appliance.
If you select this mode, the unit's input utility range will be 170~280VAC as normal home UPS.
If the utility is higher or lower than this range, the unit will transfer to inverter mode
automatically. And you can connect the computer systems or other precision home
equipment when you select this operation mode.
b). “INV.”: setting for energy saving
If you select this mode, the unit's input utility range will be extended to 90~280VAC. If the
utility is higher or lower than this range, the unit will transfer to inverter mode automatically.
So, you can connect the home equipments, such as light bulb, fluorescent tube, fan, or TV
on this mode.
Caution!!
If you select the “INV.” mode and connect the computer to the output of the unit,
the computer may reboot if the input voltage is too low to be accepted.