Table 2    External Battery Cable Size Reference   

AWG 

(American Wire Gauge 

Size)

 

Dia-mm 

(Diameter in millimeters) 

Ohms/Kft 

(Ohms per 1,000ft or 304.8 

meter) 

0000(4/0) 

11.684 

0.049 

000(3/0) 

10.405 

0.0618 

00(2/0) 

9.2657 

0.0779 

0(1/0) 

8.2513 

0.0983 

7.348 

0.1239 

6.5436 

0.1563 

5.8272 

0.197 

5.1893 

0.2485 

4.6212 

0.3133 

4.1151 

0.3962 

 
3. Product Overview 

Front View: 

 

Top View: 

 

India Type   

Universal Type 

South Africa Type     

Schuko Type   

 
Back View: 
 

 

   

 

Mounting the unit 

The unit can be mounted to a wall surface. Please follow below steps: 
1. Turn off the unit before mounting. 
2. Select an appropriate mounting location. Use a horizontal line and the length of the line 
must be 222 mm and mark the two ends on the wall. (see chart 1) 
3. Drill two marks by screws.   
4. Mount the unit by positioning the key-hole slots over the mounting screws.    (see chart 2) 

  Wall 

Chart 1 

Chart 2 

 

 

CAUTION! 

Do not disassemble the inverter. Contact with the qualified service center when 

service or repair is required. 

WARNING! 

Provide ventilation to outdoors from the battery compartment. The battery 

enclosure should be designed to prevent accumulation and concentration of hydrogen gas at 
the top of the compartment. 

CAUTION!

 Use insulated tools to reduce the chance of short-circuit when installing or working 

with the inverter, the batteries, or other equipments attached to this unit.   

CAUTION! 

For battery installation and maintenance, read the battery manufacturer's 

installation and maintenance instructions prior to operating. 

 
Personnel Precaution -   

CAUTION! 

Careful to reduce the risk or dropping a metal tool on the batteries. It could spark 

or short circuit the batteries and could cause an explosion. 

CAUTION!

 Remove personal metal items such as rings, bracelets, necklaces, and watches 

when working with batteries. Batteries can produce a short circuit current high enough to 
make metal melt, and could cause severe burns. 

CAUTION! 

Avoid touching eyes while working near batteries. 

CAUTION!

 Have plenty of fresh water and soap nearby in case battery acid contacts skin, 

clothing, or eyes. 

CAUTION! 

NEVER smoke or allow a spark or flame in vicinity of a battery. 

CAUTION! 

If a remote or automatic generator start system is used, disable the automatic 

starting circuit or disconnect the generator to prevent accident during servicing. 

 Power Switch         

 LCD Display 

 LED Indicators 

  (please see the Operation section for the details) 

 Output receptacles 

 Operation mode selector           

 AC input                                               

 Input breaker                                 

 External battery connectors       

 

Solar panel terminal 

 Solar charging indicator connection 

Содержание IPS1200A

Страница 1: ... The unit is designed for indoor use Do not expose this unit to rain snow or liquids of any type CAUTION To reduce risk of injury only use qualified batteries from qualified distributors or manufacturers Any unqualified batteries may cause damage and injury Do NOT use old or overdue batteries Please check the battery type and date code before installation to avoid damage and injury WARNING It s ve...

Страница 2: ...ompartment CAUTION Use insulated tools to reduce the chance of short circuit when installing or working with the inverter the batteries or other equipments attached to this unit CAUTION For battery installation and maintenance read the battery manufacturer s installation and maintenance instructions prior to operating Personnel Precaution CAUTION Careful to reduce the risk or dropping a metal tool...

Страница 3: ...e Please refer to Important Safety Warnings Section for the details Step 3 Tight the battery cables with the M5 nuts Do NOT place anything between the flat part of battery terminal and the battery cable ring terminal or overheating may occur See Fig 1 Step 4 Install a DC Breaker in a positive battery line The rating of the DC Breaker must be according to the inverter s battery current 75 Amp Keep ...

Страница 4: ...connection Refer to below table Model Best Vmp Vmp range 1 2KVA 15Vdc 15V 18V 2 4KVA 30Vdc 30V 32V Note Vmp panel max power point voltage The PV charging efficiency is maximized while PV system voltage is close to Best Vmp Maximum PV module numbers in Series Vmpp of PV module X pcs Best Vmp of Inverter or Vmp range PV module numbers in Parallel Max charging current of inverter Impp Total PV module...

Страница 5: ... Off Battery fully charged at power off and Off flashing every 11 sec Battery mode Battery weak and will flash every 2 second Sounding every 1 sec None weak battery Off Fault mode Fault code will be displayed Short fault F0 Overload fault F1 Battery bad F2 High output voltage F3 Main Relay Stick F4 Fan fault F5 Continuously sounding for 30 min and then alarm off The unit is overload The mark will ...

Страница 6: ...nel Battery is not connected well Check the external battery cable and terminal Make sure all the battery connections to the unit are all correct Battery defect Replace the batteries Buzzer beeps continuously and red LED is on LCD display F0 Output short circuited Check if wiring is connected well and remove abnormal load LCD display F1 Overload error The inverter is loaded with more than 110 load...

Отзывы: