2
*The fuse is located inside the DC plug. Please replace fuse with a new
equivalent value fuse.
4) Overload caused AC output reduce
*Reduce the wattage of loading to lower than 1000 watts.
5) Thermal caused AC output reduce
*Under heavy loads for extended periods of time. The AC inverter will
reduce output to prevent damage to excess heat. If this happened,
please proceed as below:
(A) Switch off the power of this inverter.
(B) Decreases the load of this machine i. e. disconnect some of the
appliances or wait until this inverter become cool.
(C) Switch on the power of this inverter.
6) Low-battery shutdown
*Recharge your battery and resume operation.
FAN
TERMINAL
( + )
TERMINAL
( - )
WARNING:DC INPUT
DO NOT REVERSE INPUT
POWER SWITCH
AC OUTPUT SOCKET
AC OUTPUT
AC
OUTLET
ON
OFF
MAIN POWER
IN FUSE
CAUTION : DO NOT REVERSE INPUT. USE RED BATTERY CORD TO
CONNECT (+) OF A DC BATTERY TO (+) TERMINAL. AND THEN, USE
BLACK BATTERY CORD TO CONNECT (-) BATTERY TO (-)
TERMINAL.
BATTERY
RED
BLACK