1
Instruction Manual
Please read user manual before use.
USEFUL APPLICATIONS
RUN NOTEBOOK COMPUTERS, RADIOS, TVS, VCRS, LAMPS, FANS, FAX,
DRILL . . . . . . ETC.
SPECIFICATION
Input voltage range : DC 10~15V (12V)
Input full load current : 100A (12V)
Standby input current : <0.6A (12V)
Output voltage (AC) : 220V~240V
Output waveform : modify sinewave
Output frequency : 50Hz or 60Hz
Continue output power : 1000W
Peak output power : 2400W
Efficiency : 85~90%
Battery low pre-alarm : 10.5 ± 0.5V (12V)
Battery low shutdown : 10 ± 0.5V (12V)
Thermal protect : 60 ± 5
℃
(microcontroller)
Auto-operation fan(Temperature or Load)
Overload protection : YES (microcontroller)
Output short protection : YES (microcontroller)
Battery ex. 12V protection : YES (microcontroller )
Battery polarity protection : YES (by fuse )
Fuse : 20A*6PCS (12V)
Transger time : 16m sec.
Charger current : MAX. 10A (12V)
Dimension ( L*W*H) mm : 430 * 135 * 79
Weight : 3.1 kg
TROUBLESHOOTING
If the inverter does not appear to be functioning properly, there are several
reasons why the inverter may not be responding.
1) Poor contact
*Cleaning contact parts thoroughly.
2) Receptacle has no power
*check fuse, replace damaged fuse.
*check receptacle wiring. repair if necessary
3) Fuse is blown