background image

Limited Lifetime Warranty

Date Purchased

Store Purchased

UL Model No.

Serial No.

Vendor No.

UPC

111017

P250007

Progress Lighting fan motors are warranted to the original purchaser to be free of electrical and/or mechanical 

defects for so long as the original purchaser owns the fan. Pull chain switches, reverse switches, capacitors and 

metal finishes are warranted to be free from defects in materials or workmanship for a period of 1 year from 

the date of purchase. Warping of wooden or plastic blades is not covered by this warranty nor is corrosion and/

or deterioration of any finishes for fans installed within ten miles of any sea coast. Extended warranties for 

ENERGY STAR

®

 qualified products may apply.

Progress Lighting ceiling fans with built-in LED light sources, when properly installed and under normal 

conditions of use, are warranted to be free from defects in material and workmanship which cause the light 

sources to fail to operate in accordance with the specifications for (i) five (5) years from the date of purchase 

on the LED Light modules and electrical components for fans used in single family residences, and (ii) three 

(3) years from the date of purchase on the LED Light modules and electrical components for fans used in 

multi-family or commercial applications. LED bulbs supplied by Progress Lighting carry no warranty other 

than manufacturer’s warranty. Non-LED bulbs carry no warranty.
With proof of purchase, the original purchaser may return the defective fan to the place of purchase during the 

first 30 days for replacement. After 30 days, the original purchaser MUST contact Progress Lighting at (864) 

678-1000 for repair or replacement which shall be determined in Progress Lighting’s sole discretion and shall 

be purchaser’s sole and exclusive remedy.
Labor  and  Shipping  Excluded.  This  warranty  does  not  cover  any  costs  or  fees  associated  with  the  labor 

(including, but not limited to, electrician’s fees) required to install, remove, or replace a fan or any fan parts.
This warranty shall not apply to any loss or damage resulting from (i) normal wear and tear or alteration, 

misuse, abuse or neglect, or (ii) improper installation, operation, repair or maintenance by original purchaser 

or a third party, including without limitation improper voltage supply or power surge, use of improper parts or 

accessories, unauthorized repair (made or attempted) or failure to provide maintenance to the fan.
THE FOREGOING WARRANTIES STATE PROGRESS LIGHTING’S ENTIRE WARRANTY OBLIGATION 

AND ORIGINAL PURCHASER’S SOLE AND EXCLUSIVE REMEDY RELATED TO SUCH PRODUCTS. 

PROGRESS LIGHTING IS NOT RESPONSIBLE FOR DAMAGES (INCLUDING INDIRECT, SPECIAL, 

INCIDENTIAL OR CONSEQUENTIAL), DUE TO PRODUCT FAILURE, WHETHER ARISING OUT OF 

BREACH OF WARRANTY, BREACH OF CONTRACT, OR OTHERWISE. THIS WARRANTY IS GIVEN 

IN LIEU OF ALL OTHER WARRANTIES, WHETHER EXPRESSED OR IMPLIED, INCLUDING THOSE 

OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE OR NONINFRINGEMENT.
Some states do not allow limitations on how long an implied warranty lasts or the exclusion or limitations 

of incidental or consequential damages, so the above limitations and exclusions may not apply to you. This 

warranty gives you specific rights and you may have other rights which vary from state to state.

785247249329
785247249312
785247249336

Содержание AirPro Claret P250007

Страница 1: ...P250007 93133616_B B...

Страница 2: ...placement After 30 days the original purchaser MUST contact Progress Lighting at 864 678 1000 for repair or replacement which shall be determined in Progress Lighting s sole discretion and shall be pu...

Страница 3: ...y Rules Unpacking Your Fan Installing Your Fan Setting the Codes Making the Electrical Connections Operating Your Fan Care of Your Fan Troubleshooting Specifications Table of Contents 1 2 3 6 7 11 12...

Страница 4: ...ing electrical connections spliced conductors should be turned upward and pushed carefully up into electrical box The wires should be spread apart with the grounded conductor and the equipment groundi...

Страница 5: ...an motor assembly 7 Blades 5 8 Light Kit Pan 9 Light Kit Fitter Assembly 10 Light Shade 11 Transmitter and Receiver 1 Mounting Bracket inside canopy 2 6 Ball Downrod Assembly hanger pin and locking pi...

Страница 6: ...rical box Note You may need a longer downrod to maintain proper blade clearance when installing on a steep sloped ceiling The maximum angle allowable is 20 If the canopy touches downrod remove the dec...

Страница 7: ...d assembly Figure 7 Remove Loosen but Do Not Remove Turn Canopy Ring to Remove Figure 5 Figure 6 5 Loosen but do not remove the set screws on the collar on the top of the motor housing 6 Align the hol...

Страница 8: ...n assembly up to the ceiling mounting bracket Make sure the tab on the mounting bracket is properly seated in the groove in the hanger ball Figure 9 Figure 8 WHEN USING THE STANDARD BALL DOWNROD MOUNT...

Страница 9: ...ery compartment on the back side of the transmitter b Slide code switches to your choice of up or down position factory setting is up c Replace the battery cover on the battery compartment of the tran...

Страница 10: ...e the wire connecting nuts supplied with your fan and supplied with remote control Secure the connectors with electrical tape Make sure there are no loose strands or connections Figure 12 1 Connect th...

Страница 11: ...BALL DOWNROD MOUNTING THE TAB IN THE RING AT THE BOTTOM OF THE MOUNTING PLATE MUST REST IN THE GROOVE OF THE HANGER BALL FAILURE TO PROPERLY SEAT THE TAB IN THE GROOVE COULD CAUSE DAMAGE TO WIRING Scr...

Страница 12: ...e from a point on the center of each blade to the point on the ceiling Measure this distance as shown in Figure 14 Rotate the fan until the next blade is positioned for measurement Repeat for each bla...

Страница 13: ...two screws Connect the wires from the light kit fitter assembly to the wires from the fan motor assembly by connecting the molded adaptor plugs together Carefully tuck all wires and splices into the...

Страница 14: ...Your fan is equipped with a remote control to operate the speed and lights of your new ceiling fan Figure 19 Model UC7085T FCC ID CHQ7085T IC 2968A 7085T Complies with Canada RSS 210 MADE IN CHINA Ai...

Страница 15: ...TION MAKING ELECTRICAL CONNECTIONS Fan will not start Fan sounds noisy 1 Check main and branch circuit fuses or breakers 2 Check line wire connections to the fan and switch wire connections in the swi...

Страница 16: ...e that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off...

Страница 17: ...Manual de instalaci n de ventilador de techo P250007 93133616_ B...

Страница 18: ...iguientes a la compra Pasados 30 d as el comprador original TIENE que contactar a Progress Lighting llamando al 864 678 1000 para reparaci n o reposici n seg n determine Progress Lighting a su entera...

Страница 19: ...el ventilador C mo instalar el ventilador C mo configurar los c digos C mo hacer las conexiones el ctricas C mo usar el ventilador Cuidado del ventilador Soluci n de problemas Especificaciones Tabla...

Страница 20: ...tores empalmados deben voltearse hacia arriba y empujarse con cuidado dentro de la caja el ctrica Los cables deben estar separados con el cable y el conductor a tierra del equipo hacia uno de los lado...

Страница 21: ...pa 5 7 Aspas 5 8 Carcasa del kit de luces 9 Conjunto de soporte del kit de luces 10 Pantalla de la l mpara 11 Transmisor y receptor 1 Soporte de montaje dentro de la cubierta 2 Conjunto de tubo bajant...

Страница 22: ...sites un tubo bajante m s largo para mantener la altura m nima adecuada de las aspas al instalar el ventilador en un techo de inclinaci n pronunciada El ngulo m ximo permitido es 20 Si la cubierta toc...

Страница 23: ...tar Gira el aro en la cubierta para quitarla Figura 5 Figura 6 5 Afloja sin quitarlos los tornillos de fijaci n en el collar n de la parte superior de la carcasa de motor 6 Alinea los orificios en la...

Страница 24: ...je est bien asentada dentro de la ranura de la bola de soporte Figura 9 Figura 8 Caja el ctrica aprobada por UL Soporte de montaje en el techo Gancho Cables de 120 V Arandela Tornillos de montaje incl...

Страница 25: ...las bater as en la parte posterior del transmisor b Desliza los interruptores de c digo como desees hacia arriba o hacia abajo la configuraci n de f brica es hacia arriba c Coloca de nuevo la cubierta...

Страница 26: ...de conexi n de cable incluidas con el ventilador y el control remoto Asegura los conectores con cinta aislante Aseg rate de que no haya conexiones ni cables sueltos Figura 12 1 Conecta el conductor a...

Страница 27: ...EN EL MONTAJE EST NDAR DE TUBO BAJANTE ESFERA LA PESTA A EN EL ARO DE LA PARTE INFERIOR DE LA PLACA DE MONTAJE TIENE QUE ENCAJAR EN LA RANURA DE LA BOLA DE SOPORTE SI NO ENCAJA BIEN LA PESTA A EN LA...

Страница 28: ...to en el techo sobre la punta de una de las aspas Mide desde un punto en el centro de cada aspa al punto en techo Mide esta distancia como muestra la Figura 14 Gira el ventilador hasta que la siguient...

Страница 29: ...unto del soporte del kit de luces a los cables del conjunto motor ventilador uniendo los enchufes moldeados del adaptador Coloca con cuidado todos los cables y empalmes dentro de la caja del interrupt...

Страница 30: ...oto que controla la velocidad y las luces de tu nuevo ventilador de techo Figura 19 Modelo UC7085T FCC ID CHQ7085T IC 2968A 7085T Cump le co n Canad RSS 210 HECHO EN CHINA Airpro R 1 2 3 4 N ECE 12V F...

Страница 31: ...ipales y secundarios 2 Verifica las conexiones de cables en l nea al ventilador y de cables del interrup tor en la caja de interruptores PRECAUCI N Aseg rate de que la fuente principal de electricidad...

Страница 32: ...radiales Sin embargo no hay garant a de que no ocurrir interferencia en cierta instalaci n particular Si este equipo causa interferencia perjudicial a la recepci n de radio o televisi n que puede det...

Страница 33: ...Guide d installation du ventilateur de plafond P250007 93133616_ B...

Страница 34: ...Progress Lighting au 864 678 1000 pour r clamer une r paration ou un remplacement selon la seule d termination de Progress Lighting et ceci constituera le seul et unique recours de l acheteur Les frai...

Страница 35: ...it D ballage du ventilateur Installation du ventilateur R glage des codes Connexions lectriques Utilisation du ventilateur Entretien du ventilateur D pannage Caract ristiques Table des mati res 1 2 3...

Страница 36: ...lectriques retournez les conducteurs piss s vers le haut et ins rez les soigneusement dans la bo te lectrique Les fils doivent tre cart s de fa on ce que le conducteur mis la terre et le conducteur de...

Страница 37: ...Moteur du ventilateur 6 Support de pale 5 7 Pales 5 8 Bac de luminaire 9 Adaptateur de luminaire 10 Abat jour de luminaire 11 metteur et r cepteur 1 Support de fixation l int rieur de la monture 2 En...

Страница 38: ...e de suspension plus longue peut s av rer n cessaire pour maintenir une distance correcte entre les pales et le plafond dans le cas d une installation sur un plafond pr sentant une forte pente L angle...

Страница 39: ...on Figure 7 Retirez Desserrez mais ne retirez pas Tournez l anneau de monture pour le retirer Figure 5 Figure 6 5 Desserrez sans les retirer les vis de pression du collet sur le dessus du bo tier du m...

Страница 40: ...ixation est correctement plac e dans le sillon de la boule de suspension Figure 9 Figure 8 Bo te lectrique homologu e cUL Support de fixation au plafond Crochet Fils de 120 volts Rondelles Vis de mont...

Страница 41: ...piles situ au dos de l metteur b Faits glisser les interrupteurs de code selon votre choix de position haute ou basse le r glage en usine est haut c Remettez le couvercle du compartiment piles sur le...

Страница 42: ...on Utilisez les capuchons de connexion fournis avec le ventilateur et la t l commande Assurez les connexions avec du ruban isolant Assurez vous qu il n y a aucun fil ou connexion desserr e Figure 12 1...

Страница 43: ...MALE AVEC LA BOULE ET LA TIGE DE SUSPENSION EST UTILIS E LA LANGUETTE DE L ANNEAU QUI SE TROUVE AU BAS DU SUPPORT DE FIXATION DOIT REPOSER DANS LE SILLON DE LA BOULE DE SUSPENSION LE C BLAGE POURRAIT...

Страница 44: ...l une des pales Mesurez la distance entre un point au centre de chaque pale et ce point au plafond Mesurez cette distance de la fa on illustr e la Figure 14 Faites tourner le ventilateur pour que la...

Страница 45: ...nectez les fils de l adaptateur de luminaire aux fils provenant du moteur du ventilateur en branchant les fiches d adaptation moul es ensemble Ins rez soigneusement tous les fils et les pissures dans...

Страница 46: ...ler la vitesse et le luminaire de votre nouveau ventilateur de plafond Figure 19 Mod le UC7085T FCC ID CHQ7085T IC 2968A 7085T Conforme a la norme RSS 210 Canada FABRIQU EN CHINE Arrpro R 1 2 3 4 N E...

Страница 47: ...1 V rifiez les fusibles ou les disjoncteurs principaux ou divisionnaires 2 V rifiez les connexions des fils de ligne au ventilateur et les connexions dans le bo tier de l interrupteur ATTENTION Assure...

Страница 48: ...74 lev e 61 5553 91 2017 Progress Lighting Inc 701 Millennium Blvd Greenville SC 29607 Tous droits r serv s Le pr sent appareil est conforme aux CNR d Industrie Canada applicables aux appareils radio...

Отзывы: