background image

Contents

  1.  Introduction ........................................................................................................................................................... 2

  2.  In general  ............................................................................................................................................................. 2

  3.  Ranges of application  ...........................................................................................................................................  2

  4.  Operation .............................................................................................................................................................. 3

  5.  Security tips ........................................................................................................................................................... 3

  6.  Servicing ............................................................................................................................................................... 3

  7.  Guarantee regulations  ..........................................................................................................................................  3

  8.  Recognising and repairing of mistakes  ................................................................................................................  4

  9.  Notes on Product Liability .....................................................................................................................................  4

10.  Notes on Disposal  ................................................................................................................................................ 4

11.  EU Declaration of Conformity  ...............................................................................................................................  4

12.  Technical Data  ...................................................................................................................................................... 8

13.  Installation scheme ............................................................................................................................................... 8

English 3

2 English

1. INTRODUCTION

We would like to congratulate you  on the purchase of our pump. We appreciate your trust. That‘s why funtional 

security and operational safety stands by us on first place.

 

 To prevent damage to persons or property, you should read this user manual carefully. Please 

observe all safety precautions and instructions for proper use of the pump. Failure to follow the 

instructions and safety precautions can result in injury or property damage.

   Please keep this manual with the instructions and safety instructions carefully in order to at any 

time you can restore them.

2. IN GENERAL

The pumps are developed according to the newest stand of technology, manufactured with much care and go under 

strict intensive controls. These pumps were optimised by us in particular for the special demands in dirty water 

areras. Make sure after unpacking the pump that the data given on the type label match with the included operating 

instructions. In case of doubt the pump is not to be used.

Transport damages are immediately to be reported to the package distributor and to us in written form.

3. RANGES OF APPLICATION

These pumps are made for pumping clear water (free of mud and sand and aggressive chemical substances (see 

technical data). The water may have to be pre-filtered to 0.2 mm particle size

The pumps are made for the following ranges of application:

l

 domestic water use from wells with diameter from 3-inch diameter

l

 circulation of large accumulations of water from containers

l

 Other plain water pumping

IMPORTANT!

The pumps are designed for pumping clean water and chemically non-aggressive liquids. Any guarantee is void in 

case of improper use. They are not suitable for pumping flammable liquids or for use in places where there is a risk  

of explosion. The pumps are designed for home use in the house and garden. 

These pumps are designed for continuous use provided (max. 20 interruptions per hour). Never run more than  

2-3 minutes against a closed valve pump. (Install dry running protection) pump adequately secured against dry running.

The pump must not be used in swimming pools.

Not suitable for use with solar photovoltaic panels.

4. OPERATION
 

The installation must be performed by a qualified professional.

 

 Please, check each time before using, the electrical connections and the cables are not damaged. Check 

before the installation whether the electrical connections are earthed according to the statutory regulations 

and are installed. The pump is to be secured through a RCD circuit breaker with release current of 30 mA. 

Also, it is NOT recommended to perform, for example, a cable extension. It is not certain whether this modi-

fication is technically correct, so this warranty is void. It must be ensured that the pump is sufficiently cooled 

during prolonged operation.

5. SECURITY TIPS

 

l

 Obey absolutely valid regulations on the electrical security 

 

l

 Never run pump dry

 

l

 Pumping inflammable, as well as all other aggressive liquids is prohibited

 

l

 Pay attention to the medium temperature max. 35°C

 

l

 Never pull the pump on the electrical cable or pressure hose

 

l

 Disconnect the plug immediately from the power grid when the line has been damaged or severed

 

l

 Avoid cross section narrowing

 

l

 Pay attention to the given particle size 

 

l

 During longer unused times, clean the pump, wash it out with clear water, dry and store it at room temperature

 

l

 Test wells for enough flowing water (dry run danger)

 

l

 The pump is to be secured through a RCD circuit  breaker with a release current of 30 mA.

 

l

 The electrical connections are always to be carried out by an authorised professional

 

l

 Operation can not be performed by children and young people under 16 and people with intellectual disabilities

THE MANUFACTURER EXPLAINS:

l

  To assume no responsibility in case of accidents or damage caused by negligence or disregard of the instructions 

in this book

l

  Any responsibility for damage caused by improper use of the pump and disregard of applicable EN - arise DIN 

standards and other standards and state of the art rejected.

6. SERVICING

 

 Under normal pumping conditions the pump requires no servicing. From an operating period (with clear 

water) of approx. 2000 hours the mechanical components should be checked: impeller wheels, chambers, 

sealing rings etc. on wear and if necessary be changed. After 3000 pumping hours the oil in the chamber 

should also be changed, if necessary (only with oil-dipped engine types!). Please, only fill it up to 80% and 

check the sealing rings always for density.

 

With abrasive materials like sand the servicing duration can become shorter.

 

The following controls should be carried out regularly:

 

l

 Intactness of the electric cable

 

l

 That the connection hoses are not bent or broken

 

l

 Cleanness of the pump medium 

 

Moreover, the pump should be emptied with risk of frost, be washed out with clear water and stored dry.

7. GUARANTEE REGULATIONS

For all manufacturing and material defects, the statutory warranty applies. In these cases we take the replacement 

or repair of the pump. Shipping costs shall be borne by our company, except as required by law. Please report the 

warranty on our service platform http://www.profi-pumpe.de/service.php. We will inform you how to proceed with 

case-related. Returns please sufficient postage. Unfortunately not prepaid returns can not be accepted because they 

are filtered out before delivery. Our service we provide in Germany.

The warranty does not cover:

l

 Improper installation (self-installation, unauthorized persons)

l

 Material wear (sealing rings, impeller wheels, impeller chambers)

l

 Unjustified interventions or changes in the pump

l

 Damages by selffault

l

 Improper servicing and improper use

l

 DRY RUNNIG (Also partially!) of the pump

Moreover, we give no damage compensation for secondary damages!

Please read the user manual before using

the pump

Warning sign

Pull power plug

Warning of electrical voltage 

SAFETY INSTRUCTION AND WARNINGS

Содержание BRUNNEN-STAR 250-5

Страница 1: ...est information about our products can be found online Technische Änderungen Druckfehler und Irrtümer vorbehalten Aktuelle Informationen zu unseren Produkten finden Sie auf http www profi pumpe de OPERATING INSTRUCTIONS BEDIENUNGSANLEITUNG de 1 BRUNNEN STAR 250 5 BP01121 2 BRUNNEN STAR 550 5 BP01123 3 BRUNNEN STAR 750 5 BP01122 ...

Страница 2: ...is warranty is void It must be ensured that the pump is sufficiently cooled during prolonged operation 5 SECURITY TIPS l Obey absolutely valid regulations on the electrical security l Never run pump dry l Pumping inflammable as well as all other aggressive liquids is prohibited l Pay attention to the medium temperature max 35 C l Never pull the pump on the electrical cable or pressure hose l Disco...

Страница 3: ...schlossenes Ventil laufen lassen Pumpe gegen Trockenlauf entsprechend sichern Trockenlaufschutz installieren Die Pumpe darf nicht in Schwimmbädern verwendet werden Nicht für Betrieb an Solar Fotovoltaikanlagen geeignet 8 RECOGNISING AND REPAIRING OF MISTAKES Problem Possible cause Solution Pump runs no water is being pumped Air in the system cannot escape Air in the system must be let out Impeller...

Страница 4: ...durch keine Garantie gewährt werden Es muss sichergestellt werden dass die Pumpe bei längerem Betrieb ausreichend gekühlt wird Pumpe stets vibrationsfrei mittels Druckschlauch anschließen Die max Zahl von 20 Schaltvorgängen pro Stunde beachten 5 SICHERHEITSHINWEISE l Unbedingt geltende Vorschriften zur elektrischen Sicherheit befolgen l Pumpe niemals trocken betreiben l Das Pumpen von entzündliche...

Страница 5: ... particle size Max Partikelgröße 0 2 mm 0 2 mm 0 2 mm Protection grade Schutzklasse IPX8 IPX8 IPX8 Electrical tension Spannung 230V 50 Hz 230V 50 Hz 230V 50 Hz Connection pressure side IT Anschluss Druckseite IG 1 IG 1 IG 11 4 IG Diameter with cable protection Durchmesser mit Kabelschutz 69 mm 70 mm 75 mm Height Höhe 960 mm 1450 mm 1165 mm Weight Gewicht 7 kg 10 kg 10 kg Cable length Kabellänge 15...

Отзывы: