PRODIGIT
3260A Series Operation Manual 5
1-5 Specification
MODEL
3261A
32611A
32612A
32613A
32614A
32615A
LOAD INPUT RATINGS
Power (VA)
Current(Ampere)
Voltage(Volt)
1800 VA
18 Arms
50~300 Vrms
3600 VA
36 Arms
50~300 Vrms
5400 VA
54 Arms
50~300 Vrms
7200 VA
72 Arms
50~300 Vrms
9000 VA
90 Arms
50~300 Vrms
10800 VA
108 Arms
50~300 Vrms
PROTECTION
:
Over Power Protection
Over Current Protection
Over Voltage Protection
Over Temp. Protection
≒
1890 VA
≒
18.9 A
≒
315 V
85
℃
≒
3780 VA
≒
37.8 A
≒
315 V
85
℃
≒
5670 VA
≒
56.7 A
≒
315 V
85
℃
≒
7560 VA
≒
75.6 A
≒
315 V
85
℃
≒
9450 VA
≒
94.5 A
≒
315 V
85
℃
≒
11340 VA
≒
113.4 A
≒
315 V
85
℃
Range
0~9/9~18
A
0~18/18~36
A
0~27/27~54
A
0~36/36~72
A
0~45/45~90
A
0~54/54~108
A
Resolution 2.25/4.5 mA
4.5/9 mA
6.75/13.5 mA
9/18 mA
11.25/21.5 mA
13.5/27 mA
Accuracy
±
(
0.5
﹪
of setting
+
1
﹪
of range
);
±0.5
﹪
of
(
setting
+
range
)
@ 50/60Hz
0~0.9 A
0~1.8 A
0~2.7 A
0~3.6 A
0~4.5 A
0~5.4 A
CC MODE
&
Linear CC
MODE
Low
Current
Accuracy
± 2 % of (s range)
Range II/I
3.333~13.33
2~53.332K
1.667~6.668
~26.668K
1.111~4.444
~17.776K
0.833~3.333
~13.33K
0.666~2.666
~10.666K
0.556~2.224
~8.888K
Resolution
0.019/0.076
mS
0.037/0.148
mS
0.056/0.224
mS
0.075/0.300
mS
0.0937/0.375
mS
0.113/0.452
mS
Accuracy
(
0.5
﹪
of setting
+
2
﹪
of range
);
±0.5
﹪
of
(
setting
+
range
)
@ 50/60Hz
CR MODE
Under 5
﹪
F.S.Current
±2
﹪
of
(
setting
+
range
)
Range
√2 ~ 3.5 / 1.5 ~ 1.9 / 3.0 ~ 3.4
CREST
FACTOR
(CCMODE
ONLY)
Resolution
0.5 / 0.1 / 0.1
VOLTAGE
Range
300 V
300 V
300 V
300 V
300 V
300 V
READBACK Resolution
0.1 V
0.1 V
0.1 V
0.1 V
0.1 V
0.1 V
V METER
Accuracy
±( 0.5
﹪
of reading
+
0.2
﹪
of range )
DVM under 1% don’t display.
CURRENT
Range
18 A
36 A
54 A
72 A
90 A
108 A
READBACK Resolution
0.001 A
0.01 A
0.012 A
0.012 A
0.01 A
0.012 A
A METER
Accuracy
±
(
0.5
﹪
of reading
+
2
﹪
of range
);
±0.5
﹪
of
(
reading
+
range
)
@ 50/60Hz
WATT
Range
1800 W
3600 W
5400 W
7200 W
9000W
10800 W
READBACK Resolution
0.1 W
1 W
1.2 W
1.2 W
1W
1.2 W
Accuracy
±
(
0.5
﹪
of reading
+
2
﹪
of range
);
±0.5
﹪
of
(
reading
+
range
)
@ 50/60Hz
W METER
Under 5
﹪
F.S.Current
±3
﹪
of
(
setting
+
range
)
VA METER
Vrms×Arms Correspond To Vrms and Arms
FREQUENCY Range
DC , 40~400 Hz(CC Mode) ; DC , 0.1~400 Hz(LIN,CR Mode)
Imonitor
(
Isolated
)
4.5 A/V
9 A/V
13.5 A/V
18 A/V
22.5A/V
27 A/V