42 PRODIGIT
LIN
Purpose
:
:
:
:
The load linear current setting in Constant Current mode.
Command syntax
:
:
:
:
LIN
:
{LOW|HIGH|A|B}{SP}{NR2}{NL}
Description
:
:
:
:
This command is used to set the load current LEVEL A/B of 3260A series Electronic
Load.
Note:
1. The load current data must include decimal point, otherwise this command is
unable to execute. The effective load current level can be programmed is the sixth
digit after the decimal point.
2. The HIGH load level load current MUST be higher than LOW level load current for
proper dynamic waveform definition, the load current difference between
programmed HIGH and LOW level is 10 times of resolution at each range, the
3260A series Electronic Load will adjust and limit of the programmed values.
3. If the programming loads current level over the maximum specification at
programmed range of 3260A series load, the full scale current will be sent to the
load module.
4. Engineering unit for load current is Amps.
For Example
:
:
:
:
LIN
:
A 1.8 ; Set level A load linear current to 1.8 A.
LIN
:
B 15.123456 ; Set level B load linear current to 15.123456 A.
LOAD
Purpose
:
:
:
:
Turn the Electronic load module input ON or OFF.
Command syntax
:
LOAD{SP}{0FF|ON}{NL}
Description
:
:
:
:
This command sets the Electronic load to sink current from AC/DC power source.
LOAD ON the 3260A series Electronic load are ready to sink current from AC/DC
power source.
For Example
:
:
:
:
LOAD 0 ; Set the load "LOAD OFF".
LEV
Purpose
:
:
:
:
Select LEVEL A or B of 3260A series electronic load.
Command syntax
:
LEV{SP}{0|1|A|B}{NL}
Description
:
:
:
:
LEV A The condition and setting of electronic load adopt the set value of LEVEL A.
LEV B The condition and setting of electronic load adopt the set value of LEVEL B.