![Procopi Proswell Tropic HEXA Скачать руководство пользователя страница 24](http://html1.mh-extra.com/html/procopi/proswell-tropic-hexa/proswell-tropic-hexa_installation-instructions-manual_1609046024.webp)
» INSTALLATION INSTRUCTIONS
/ OCTO / OCTO + / HEXA
24
proswell.fr
58
Connect the rigid descending pipes to the filtration group as shown above. The roll of tubing provided in the Filtration
kit is sized for a standard installation, that is to say, with the filter group located 3.5 m from the pool (minimum distance
between the pump and the pool according to the French electrical safety standard
C15-100 if the filtration group is not
installed in a locked plant room).
Check that all the valves are closed and continue to fill the pool until the water level is 2/3 of the way up the mouth of the
skimmer. This is the optimum level for correct filter operation.
While filling, check the various fittings for leaks. Make sure that the liner is properly engaged in the liner locking track
around the entire periphery of the pool, particularly in the corners. If the liner has come away it will usually be necessary
to empty the pool in order to reattach it.
Open the various valves to fill the circuit with water. Check the various connection points for leaks.
Make sure that the pump is filled with water before starting it up. The pump should under no circumstances be allowed to
run dry. Make sure that the pre-filter is filled with water. If necessary, open the pump and fill it and the skimmer line with
water to facilitate priming.
Turn the 6-way valve to Backwash (to carry out a filter backwash before putting the filter into service).
Start the pump and check again for leaks.
CHARGING THE CIRCUIT WITH WATER
>>
PLUMBING
FILLING THE POOL
TIP:
You may use silicon grease or soapy water to help fit the pipes together.
>>
FILLING AND CHARGING THE CIRCUIT WITH WATER
suction
return