11. Turn control knob counterclockwise
to the ON position. The main burner
should light.
Note: Please wait one minute after shut-
ting off fireplace to allow the control valve
to reset before starting again.
12. Press the LEARN BUTTON on the front of
the remote receiver box until you hear a
beep (see
Programming the Remote and
Receiver
, page 21).
13. Press the ON button on the remote control
transmitter to light the burner. (This will
also “learn”, or program, the transmitter
and the receiver).
Note: If the transmitter is lost or damaged,
the slide switch on the receiver can be
used to operate the heater.
CAUTION: Do not try to ad-
just heating levels by using the
equipment shutoff valve.
WARNING: If input gas
type is NG, make sure NG pilot
burner ignites. If input gas type
is LP, make sure LP pilot burner
ignites.
Note: The first time that the heater is
operated after connecting the gas supply,
the control knob should be pressed for
about thirty (30) seconds. This will allow
air to bleed from the gas system. If pilot
does not stay lit, refer to Troubleshooting,
pages 26 though 28. Also contact a quali-
fied service technician or gas supplier for
repairs. Until repairs are made, light pilot
with match.
• If control knob does not pop up when
released, contact a qualified service
technician or gas supplier for repairs.
9. With control knob pressed in, push
down and release ignitor button. This
will light pilot. The pilot is attached to
the rear of the burner. If needed, keep
pressing ignitor button until pilot lights.
Note: If pilot does not stay lit, refer to
Troubleshooting, page 26. Also contact a
qualified service technician or gas supplier
for repairs. Until repairs are made, light
pilot with match. To light pilot with match,
see Manual Lighting Procedure.
10. Keep control knob pressed in for 30 sec-
onds after lighting pilot. After 30 seconds,
release control knob.
Note: If pilot goes out, repeat steps 7
through 10. This heater has a safety in-
terlock system. Wait one (1) minute before
lighting pilot again.
OPERATION
Shutting Off Heater
Turn control knob clockwise
to the
OFF position.
Shutting Off Burner Only (pilot
stays lit )
Turn control knob clockwise
to the
PILOT position.
1. Follow steps 1 through 7 under
Lighting
Instructions
, page 19.
2. With control knob in PILOT position, strike
match, and hold near pilot. Press in control
knob; pilot should light.
3. Keep control knob pressed in for 30 sec-
onds after lighting pilot. After 30 seconds,
release control knob.
4. Make sure the heater screen is in place
before operating heater.
TO TURN OFF GAS TO APPLIANCE
MANUAL LIGHTING PROCEDURE