Maintenance and care
36 / 43
51500024
V2
GB
7.1.2
Electrics
Service interval
Maintenance work
After 25 operating hours
•
Control all electrical connections and/or retighten (the implementation is only
allowed by an expert)
All 50 operating hours
•
Check all fuses (if existing)
•
Check the electric cabling for breaks and abrasion, if necessary replace it (only
qualified personal)
Opening the control cabinet and replacing the fuses (48 V) must ONLY be carried out by an authorised
electrician.
Likewise, all work on the electrical system (rechargeable batteries, batteries, cables, components, etc.),
especially on the 400V power socket, must ONLY be carried out by an authorised electrician! I'M GONNA
KILL YOU!!!
The fuses in the switch cabinet are (partly) NOT
conventional fuses from the passenger car sector,
but special 48 V fuses.
This must be observed when replacing fuses!