![probst 5220.0011 Скачать руководство пользователя страница 29](http://html1.mh-extra.com/html/probst/5220-0011/5220-0011_manual_1608367029.webp)
Operating
JUMBO-BV-VARIO-B
V2
26/07/16
28 / 40
●
Place the vacuum head directly above the load/kerb stone.
●
Press the regulator lever (1) down. The lifting tube descends and
the vacuum head lowers.
●
Apply the vacuum head to the load. Distribute load evenly.
●
Slowly push the regulator lever (1) upward. The device attaches
to the load.
Control lever (of operating valve unit) must not be on the position “Lift”, for more than 90 seconds.
Because otherwise the blower could be damaged and fail, (all guarantee claims are void) and power is
wasted unnecessarily.
6.3.2
Adjusting the hovering position with load
Turn the adjusting screw (2) to adjust the hovering position with
the load.
Caution
: Do not confuse this adjustment with the hovering
position without load.
Turn screw clockwise
the hovering
position will be lower.
Turn screw counter-clockwise
the hovering
position will be higher.
Control lever (of operating valve unit) must not be on the position “Lift”, for more than 90 seconds.
Because otherwise the blower could be damaged and fail, (all guarantee claims are void) and power is
wasted unnecessarily.
The hovering position with load should not be adjusted to the highest position of the lifting hose unit
because otherwise: the blower could be damaged and fail,
(all guarantee claims are void) and power is wasted unnecessarily.
Содержание 5220.0011
Страница 59: ......
Страница 60: ......
Страница 83: ...Hubeinheit mit Bedieneinheit Ersatzteile Spare Parts Hubeinheit Lifting Hose Assy Dreheinheit Rotation Unit...