Adjustments
HVZ-uni
V7
18/06/12
16 / 36
6.2.1
Settings of the main gripping direction
The gripping direction, activated from the single hydraulic cylinder, holding the paver layer with the steel
lamellas is called main gripping direction.
The following diagram is attached to the HVZ-uni.
Opening width
in mm
Adjustments
OW min
in mm
OW max
in mm
600
A1
B6
D0
E0
F4
I1
570
770
650
A1
B6
D0
E1
F4
I1
570
770
700
A1
B5
D1
E4
F6
I2
630
830
750
A2
B5
D2
E5
F7
I3
680
880
800
A3
B5
D3
E6
F7
I3
730
930
850
A3
B4
D6
E8
F9
I6
800
1000
900
A3
B4
D6
E7
F9
I5
800
1000
950
A3
B3
D6
E9
F10
I6
870
1070
1000
A3
B2
D6
E11
F12
I7
940
1140
1050
A3
B2
D8
E10
F11
I8
940
1140
1100
A3
B1
D9
E12
F12
I9
1010
1210
1150
A3
B1
D10
E11
F11
I10
1010
1210
1200
A3
B1
1250
A3
B1
picture 1