2.1 Important technical data:
Important technical data:
Important technical data:
Important technical data:
Boiler:
Boiler:
Boiler:
Boiler:
Measure:
Comments:
Model
PROBOIL.4E
Boiler type
Vented (unpressurised) displacement system
Unit dimensions
206x256x291mm (without connectors attached)
Overall weight
9 kg (Apx. when full)
Ambient operating temperature
+5°C to +40°C (indoor use heated space only)
Minimum cold input pressure
2 bar (recommended), assuming a minimum acceptable flow rate of 1 litre
per minute.
Maximum cold input pressure
5.5 bar, if incoming cold water pressure is above this value than a pressure
reducing valve must be installed.
Boiling tank capacity
4 /- 5%
Typical usable volume
Dependent on temperature selection, when set to 98°C approximately 3.0
litres above 90° and approximately 1.5 litres before incoming cold water
decrease the output temperature when dispensed continuously.
Maximum Chlorine value for
incoming water
100mg/l
Tank material
Stainless steel (304)
Selectable in tank temperatures
98° Maximum with adjustable heating point adjustment on screen
(75, 85, 90, 95, 96, 97- 98°C range)
Heat up time
From 20°C to 98°C
1 litre usage recovery, approximate time 18 minutes
2 litre usage recovery, approximate time 12 minutes
3 litre usage recovery, approximate time 8 minutes
4 litre usage recovery, approximate time 9 minutes
Up to apx. 100 UK cups per hour dependant on environmental and usage
conditions
Thermal loss
Apx. 3-4°C. loss from tank to spout exit
Varies according to tap model, environmental and usage conditions
Safety devices
-
vented (unpressurised) tank
-
minimum water level float switch to prevent dry heating
-
digital thermal monitoring and control
-
digital self-diagnostic control
-
one shot dry burn 120°C thermal fuse (non-resettable)
-
blow off connection for accidental blockage protection
Supply voltage range
AC 220-240V (50Hz)
Max. Power usage
(element on)
2.15kW at 240V AC
Power usage
Standby (screen off)
0.5W
Power usage
(keep warm at 98°C)
0.043kWh, depending on ambient temperature, power on, no water usage.
Power usage
(reboil 1 litre at 98°C)
0.1kWh (based on single 1 litre dispense of 98°C)
Power lead
1.4M (cable), 3 pin UK plug (13A), IEC connector, do not extend or replace.
Filter
Filter
Filter
Filter cartridge