This manual covers the following models:
• T925

INSTALLATION MANUAL

A trained, experienced technician 
must install this product.

Carefully read these instructions. You 
could damage this product or cause a 
hazardous condition if you fail to follow 
these instructions.

Need Help?

For assistance with this product please 

visit http://www.pro1iaq.com or call Pro1 

Customer Care toll-free at 888-Pro1iaq 

(776-1427) during normal business hours 

(Mon-Fri 9 AM - 6 PM Eastern)

Table of Contents

Thermostat Applications Guide

Page

Battery Power
Hardwire (Common Wire)
Hardwire (Common Wire) with Battery Backup

Power Type

1

n

o

it

p

ir

c

s

e

D

Gas or Oil Heat
Electric Furnace
Heat Pump (No Aux. or Emergency Heat)
Heat Pump (with Aux. or Emergency Heat)
Multi-stage Systems
Heat Only Systems
Cool Only Systems
Millivolt

No
No

Yes
Yes

No
No
No
No

Rev. 0730

Una versión española de este 
manual puede ser descargada 
en www.pro1iaq.com

® U.S. Registered Trademark. Patents pending.
Copyright © 2006 Pro1 IAQ, Inc. All rights reserved.

Installation Tips
Thermostat Quick Reference
Subbase Installation
Wiring
Technician Setup Menu 
Mounting and Battery Installation
Programming The Thermostat
Specifications

2
3
4
5

6, 7, 8 

9

10, 11, 12

13

Содержание T925

Страница 1: ...s Guide Page Battery Power Hardwire Common Wire Hardwire Common Wire with Battery Backup Power Type 1 n o i t p i r c s e D Gas or Oil Heat Electric Furnace Heat Pump No Aux or Emergency Heat Heat Pum...

Страница 2: ...ld air ducts That are in direct sunlight With an outside wall behind the thermostat In areas that do not require conditioning Where there are dead spots or drafts in corners or behind doors Where ther...

Страница 3: ...different options during programming Indicates the current room temperature Programmable Time Period Icons This thermostat has 4 programmable time periods per day Important The low battery indicator...

Страница 4: ...Pro1 s products are mercury free However if the product you are replacing contains mercury dispose of it properly Your local waste management authority can give you instructions on recycling and prope...

Страница 5: ...nal connections on the thermostat that is being replaced In some cases the wiring connections will not be color coded For example the green wire may not be connected to the G terminal Loosen the termi...

Страница 6: ...es and a larger swing setting will cause fewer cycles Keypad lockout allows you to configure the thermostat so that none or some of the keys do not function The heating swing setting is adjustable fro...

Страница 7: ...AKE time period begins This recovery changes over time based on the previous days experience Morning Recovery Use the or key to select 7d for 7 day 5d for 5 1 1 or 0d for nonprogammable 5d You can con...

Страница 8: ...display if there has been a continuous call for heating or cooling for 24 hours or if the light button is held down for 3 seconds To remove the phone number from the display hold the light button dow...

Страница 9: ...LATION Mount Thermostat Align the 4 tabs on the subbase with corresponding slots on the back of the thermostat then push gently until the thermostat snaps in place On the back of the thermostat insert...

Страница 10: ...etting to select the current day of the week Press NEXT STEP The current hour is flashing Use the or key below the time setting to select the current hour When using 12 hour time make sure the correct...

Страница 11: ...KE time period Note If you want the fan to run continuously during this time period select ON with the FAN key Use the or temperature setpoint keys on the right side of your screen to make your temper...

Страница 12: ...e weekday WAKE period Press NEXT STEP Repeat steps 4 thru 6 for Monday LEAVE time period for Monday RETURN time period and for Monday SLEEP time period Repeat steps 4 thru 7 for each of the remaining...

Страница 13: ...7 C to 32 C 1 amp per terminal 1 5 amp maximum all terminals combined 1 F Heating is adjustable from 0 4 F to 2 0 F Cooling is adjustable from 0 4 F to 2 0 F 18 to 30 VAC NEC Class II 50 60 Hz for ha...

Отзывы: