TECHNICIAN SETUP MENU

TECH SETUP

STEPS CONTINUED

ON THE NEXT PAGE

Use the         or 

key to select the 

maximum heat 

setpoint.

90 ºF

Adjustment Options

Factory Default Settings

This feature 

allows you to set a 

maximum heat 

setpoint value. 

The setpoint 

temperature

cannot be raised 

above this value.

Tech Setup Steps (Continued from the previous page)

Heating

Temperature 

Setpoint Limit

LCD Will Show

Use the         or 

key to select the 

minmum cool 

setpoint.

44 ºF

This feature 

allows you to set a 

minimum cool 

setpoint value. 

The setpoint 

temperature

cannot be lowerd 

below this value.

Cooling

Temperature 

Setpoint Limit

Use the         or 

key to select 12 or 24 

hour clock.

12 Hour Clock

You can select 

either a 

12

 or 

24

hour clock setting.

12 or 24

Hour Clock

Use the         or 

key to turn on or off.

ON

This feature turns your 

system on before the 

WAKE

 programming 

time to ensure the 

enviroment is at the 

WAKE

 setpoint when 

the

WAKE

 time period 

begins. This recovery 

changes over time 

based on the previous 

days experience.

Morning

Recovery

Use the         or 

key to select 

7d

for 7 

day, 

5d

 for 5+1+1, 

or

0d

 for 

nonprogammable.

5d

You can configure this 

thermostat to have a 

7 day program, a 

5+1+1 program or 

nonprogrammable.

Program

Options

Select

F

 for 

Fahrenheit 

temperature read 

out or select 

C

 for 

Celsius read out

ºF for Fahrenheit

ºC for Celsius 

ºF

ºF or ºC

OFF

 configures 

display light to come 

on only with the light 

key, which will save 

battery power.

ON

 configures the 

display light to come 

on when any key is 

pressed.

ON

The display light can 

be configured to 

come on when any 

key is pressed or 

only when the light 

key is pressed. 

Display

Light

The second stage will turn on at 2x the swing setting. The second stage will turn off when 1x the 

swing is reached. For example, if the swing setting is .8 degrees for heating and the thermostat is 

set at 70ºF, the first stage will turn on at approximately 69.2ºF. The second stage will turn on at 

68.4ºF. The second stage will turn off at 69.2ºF and the first will turn off at 70.8ºF.

PRO1 Tip

Содержание T925

Страница 1: ...s Guide Page Battery Power Hardwire Common Wire Hardwire Common Wire with Battery Backup Power Type 1 n o i t p i r c s e D Gas or Oil Heat Electric Furnace Heat Pump No Aux or Emergency Heat Heat Pum...

Страница 2: ...ld air ducts That are in direct sunlight With an outside wall behind the thermostat In areas that do not require conditioning Where there are dead spots or drafts in corners or behind doors Where ther...

Страница 3: ...different options during programming Indicates the current room temperature Programmable Time Period Icons This thermostat has 4 programmable time periods per day Important The low battery indicator...

Страница 4: ...Pro1 s products are mercury free However if the product you are replacing contains mercury dispose of it properly Your local waste management authority can give you instructions on recycling and prope...

Страница 5: ...nal connections on the thermostat that is being replaced In some cases the wiring connections will not be color coded For example the green wire may not be connected to the G terminal Loosen the termi...

Страница 6: ...es and a larger swing setting will cause fewer cycles Keypad lockout allows you to configure the thermostat so that none or some of the keys do not function The heating swing setting is adjustable fro...

Страница 7: ...AKE time period begins This recovery changes over time based on the previous days experience Morning Recovery Use the or key to select 7d for 7 day 5d for 5 1 1 or 0d for nonprogammable 5d You can con...

Страница 8: ...display if there has been a continuous call for heating or cooling for 24 hours or if the light button is held down for 3 seconds To remove the phone number from the display hold the light button dow...

Страница 9: ...LATION Mount Thermostat Align the 4 tabs on the subbase with corresponding slots on the back of the thermostat then push gently until the thermostat snaps in place On the back of the thermostat insert...

Страница 10: ...etting to select the current day of the week Press NEXT STEP The current hour is flashing Use the or key below the time setting to select the current hour When using 12 hour time make sure the correct...

Страница 11: ...KE time period Note If you want the fan to run continuously during this time period select ON with the FAN key Use the or temperature setpoint keys on the right side of your screen to make your temper...

Страница 12: ...e weekday WAKE period Press NEXT STEP Repeat steps 4 thru 6 for Monday LEAVE time period for Monday RETURN time period and for Monday SLEEP time period Repeat steps 4 thru 7 for each of the remaining...

Страница 13: ...7 C to 32 C 1 amp per terminal 1 5 amp maximum all terminals combined 1 F Heating is adjustable from 0 4 F to 2 0 F Cooling is adjustable from 0 4 F to 2 0 F 18 to 30 VAC NEC Class II 50 60 Hz for ha...

Отзывы: