OPERATION
© 2018 Global Welding LLC
Page
29
Operating Manual No: PWOM-215/250MP-001
STICK
Provides
built-in STICK weld settings for the selected metal
thickness. Press Multi-Function Control (F) to select STICK.
Refer to
NOTE
18
.
Select
Welding Electrode Selection
: E60xx or 70xx
Select
Welding Diameter Selection
:
3/32’’ / 1/8’’ (215MP/250MP) on 120 VAC
3/32’’ / 1/8’’ / 5/32’’ (215MP) on 208/230/240 VAC
3/32’’ / 1/8’’ / 5/32’’ / 3/16’’ (250MP) on 208/230/240 VAC
Select metal
Thickness
being welded
HELP
Provides
information of Software Version, Units of measure
selection or Factory Reset.
Press Multi-Function Control (F) to select:
VERSION
--- Display Software Version in product.
UNITS ---
Sets
Units of measure to mm (millimeters) or
Inch in product.
FACTORY RESET ---
Resets all welding parameters and
deletes all saved weld parameters in memory. Select
YES
to
Restore Factory Settings
then
YES
again to com-
plete the restore.
5.4
Memory Save/Recall
Frequently used welding parameters can be saved then re-
called as needed. Memory Save/Recall can be used for MIG
SYN, MIG MAN, TIG or STICK parameters.
NOTE
19
: A total of 9 memory locations are available to
save/recall welding parameters.
1.
SAVE Welding Parameters to Memory
-
Adjust controls to achieve a suitable weld result.
-
Press
(I).
-
Rotate
(F)
to select an unused Memory location.
-
Press
(F)
to
Save
welding parameters.
-
Press
(F)
again on
YES
to confirm
SAVE TO MEMORY
or
NO
to cancel.
-
To return to the previous screen rotate
(F)
to select
BACK
then press
(F).
2.
RECALL Welding Parameters from Memory
-
From the
WELD MODE SELECTION
screen press
(I)
.
-
Rotate
(F)
to select a previously saved weld parame-
ters Memory location.
5.5
ERROR Displays
Refer to description number 13 (
Over Temperature ERROR
displayed on screen
) or 14 (
Over Current ERROR
displayed on
screen