FAULTS EXIST
Faults currently exist.
Correct the cause of the fault.
Press reset to reset the fault con-
dition once the cause is cor-
rected.
CARRIAGE MOVING
UP TOO SLOWLY
The carriage is moving upward too slowly.
Check for the cause of the car-
riage not moving correctly.
Check the belt drive behind the
back panel. Check for a jam or
obstruction on the track.
CARRIAGE MOVING
DOWN TOO SLOWLY
The carriage is moving downward too slowly.
Check for the cause of the car-
riage not moving correctly.
Check the belt drive behind the
back panel. Check for a jam or
obstruction on the track.
MULTISTRETCH VFD
NOT READY
The indicated VFD is not ready to run.
Check the fault code on the VFD
display in the electrical cabinet.
See VFD manual for fault code
information.
MAIN DRIVE VFD NOT
READY
CARRIAGE VFD NOT
READY
DOWNLOADING VFD
PARAMETERS -
PLEASE WAIT
The VFD parameters are transferring to the
VFD’s from the PLC.
Wait until the process is com-
pleted.
X2X
COMMUNICATION
FAULT - PRESS E-STOP
TO CLEAR FAULT
There is an X2X communication fault, press and
release the E-stop button to clear the fault.
Contact Orion Packaging if
problem persists.
RS485
COMMUNICATION
FAULT - PRESS E-STOP
TO CLEAR FAULT
There is an RS485 communication fault, press
and release the E-stop button to clear the fault.
Contact Orion Packaging if
problem persists.
Table 3-36. The Information and Alarm Displays (Continued)
MESSAGE
DESCRIPTION
CORRECTION
Содержание ORION Sentry HP
Страница 1: ...Revision Date May 21 2020 Revision 3 1 Sentry HP LP STRETCHWRAPPER MANUAL...
Страница 30: ...Machine Manual Orion Sentry HP LP Flex Stretchwrapper Revision 3 1 System Description 21 May 2020 Page 2 4...
Страница 88: ...Machine Manual Orion Sentry HP LP Flex Stretchwrapper Revision 3 1 Troubleshooting Contents 21 May 2020 Page II...
Страница 92: ...Machine Manual Orion Sentry HP LP Flex Stretchwrapper Revision 3 1 Maintenance Contents 21 May 2020 Page II...