System Operation
Page 3-35
Orion Carriage Multistretch Settings Screen
This is the Multistretch Settings screen. This page is useful primarily to repair personnel
when troubleshooting the machine.
Figure 3 - 30
The Orion Carriage
Multistretch Screen
Table 3-26. The Orion Carriage Multistretch Screen Button Descriptions
STATE 1
DESCRIPTION
ZERO TRIM
Press this button to modify the Zero Trim datapoint, in terms of milliamps. This
value determines at which point the Multistretch will begin paying out film as the
dancer bar is deflected. This value should be .5 mA higher than the Hall Effect Sen-
sor reading with the dancer bar at rest. Min - 3.mA Max - 8 mA
GAIN
Press this button to modify the Gain datapoint, in terms of percentage. This value
sets percentage of deflection of the dancer bar that is required for the Multistretch to
pay out film at maximum speed. Min - 10% Max - 100%
SENSOR (MA) VALUE
This displays the current dancer bar Hall Effect Sensor reading, in terms of milli-
amps.
MODIFY SETTINGS
Press this button for access to modify the Zero Trim or Gain datapoints.
The Multistretch is disabled while modifying the datapoints.
APPLY SETTINGS
Press this button to accept the current Zero Trim and Gain datapoints and apply
them to the Multistretch. When complete, the drive will be enabled again.
TENSION UP %
Press this button to enter the film tension percentage from 0-100% while the car-
riage is traveling up.
TENSION DOWN %
Press this button to enter the film tension percentage from 0-100% while the car-
riage is traveling down.
Содержание ORION Sentry HP
Страница 1: ...Revision Date May 21 2020 Revision 3 1 Sentry HP LP STRETCHWRAPPER MANUAL...
Страница 30: ...Machine Manual Orion Sentry HP LP Flex Stretchwrapper Revision 3 1 System Description 21 May 2020 Page 2 4...
Страница 88: ...Machine Manual Orion Sentry HP LP Flex Stretchwrapper Revision 3 1 Troubleshooting Contents 21 May 2020 Page II...
Страница 92: ...Machine Manual Orion Sentry HP LP Flex Stretchwrapper Revision 3 1 Maintenance Contents 21 May 2020 Page II...