PS-4000B Series User Manual
46
Environmental Characteristics
Characteristics
The environmental characteristics of the PS-B unit are as follows:
Characteristics Value
Standards
Degree of Protection
IP 20
EN/IEC 61131-2
Pollution Degree
For use in Pollution Degree 2 environment EN/IEC 61131-2
Surrounding air temperature
during operation
0...50
C (32...122
F)
*1
EN/IEC 61131-2, UL508
Storage temperature
– 20...60
C (– 4...140
F)
IEC 60068-2-2 tests Bb and Ab,
IEC 60068-2-14 tests Na and EN/IEC
61131-2
Operating altitude
2000 m (6560 ft) max
EN/IEC 61131-2
Vi
b
ra
tio
n
*2
Operation (continuous)
for products with SSD or
CF Card storage device.
2-9 Hz: 1.5 mm
9-200 Hz: 4.9 m/s
2
IACS E10 and EN/IEC 60068-2-6 Fc
5-8.4 Hz: 1.75 mm
8.4-150 Hz: 4.9 m/s
2
Operation (continuous)
for products with HDD
storage device.
5-100 Hz: 1.225 m/s
2
Operation (occasional)
for products with SSD or
CF Card storage device.
2-9 Hz: 3 mm
9-200 Hz: 9.8 m/s
2
5-8.4 Hz: 3.5 mm
8.4-150 Hz: 9.8 m/s
2
Operation (occasional)
for products with HDD
storage device.
5-100 Hz: 2.450 m/s
2
Merchant navy
(continuous)
3-13.2 Hz: 1mm (0.04 in.)
13.2-100 Hz: 6.9 m/s
2
Shock Resistance (in
operation)
147 m/s
2
/ 11 ms
Surrounding air humidity
during operation
10...85 % RH (Wet bulb temperature: 29
C
(84.2
F) max. - no condensation)
EN/IEC 60068-2-78 Ca
Storage humidity
10...85 % RH (Wet bulb temperature: 29
C
(84.2
F) max. - no condensation)
EN/IEC 60068-2-30 Db
Electromagnetic Compatibility
(EMC)
Immunity to High Frequency Interference
EN/IEC 61131-2, IEC 61000-4x
Electromagnetic Emissions Class A
EN 55022/55011
*1
Surrounding air temperature depends on what feature or option you use.
When you use PS-B unit without FAN unit (AtomN270)
0...45
C(32... 113
F) when using Gigabit Ether
5...40
C(41... 104
F) when using DVD-RW
When you use PS-B unit with FAN unit (Core2Duo P8400)
5...50
C(41... 122
F) when using DVD-RW
*2
Even when the product is used in the specifications noted above, the HDD access performance may be
decreased due to the vibrational component.
Please execute an evaluation in the actual installation environment. It is recommended to use an SSD in the
environment where the vibration may have an impact on the performance.
Содержание PS-4000B Series
Страница 1: ...36 6HULHV 8VHU 0DQXDO...
Страница 12: ...PS 4000B Series User Manual 12...
Страница 14: ...PS 4000B Series User Manual 14...
Страница 60: ...PS 4000B Series User Manual 60...
Страница 74: ...PS 4000B Series User Manual 74...
Страница 95: ...Hardware Modifications 95 The following figure shows the dimensions of the UPS battery unit...
Страница 110: ...PS 4000B Series User Manual 110...
Страница 112: ...PS 4000B Series User Manual 112...
Страница 132: ...PS 4000B Series User Manual 132...
Страница 134: ...PS 4000B Series User Manual 134...
Страница 138: ...PS 4000B Series User Manual 138...