shmrp [5-25]
: periodicity of the light bursts during the clash effect. A slow
period will produce tight bursts.
shmrr [0-25]
: random value applied to the periodicity of the light burst
during a clash effect. Allows having bursts that are not regularly spaced in time
which increases the realism. For instance, a period
shmrp
of 20 and a random
value
shmrr
of 10 will produce a period between two bursts varying between
20 and 30 (ie 40 and 60 ms).
shmr% [0-100],[0-100]
: shimmer effect depth. Defines how the shimmer
will "dig" the defined brightness during a clash or a lockup effect. A static flash
is achieved by leaving that value to 0. That parameter is actually composed of
2 numbers separated by a comma to define the range to apply to the
brightness modification during the shimmer.
focd [0-500]
: Flash on Clash™ (FoC™) duration. Used when an extra LED
die is wired to the board with a Power Xtender™ circuit and the Flash on
Clash™ Pad.
focp [5-25]
: periodicity of the light bursts during the Flash on Clash™
effect. A slow period will produce tight bursts. Similar to the
shmrp
parameter.
focr [0-25]
: random value applied to the periodicity of the light burst during
a Flash on Clash™ effect. Similar to
shmrr
but applied to FoC™.
foc% [0-100] ,[0-100]
: Flash on Clash effect depth. Defines how deep
the FoC brightness is dug for “on-top” (or non-mixed) FoC di(c)e. Also
composed of 2 comma-separated numbers, like the shimmer depth (see
above).
Saber / User interaction parameters :
switch [0-2]
: selects if the saber is activated by a normally-open or a
normally-closed switch. Certain “push-on push-off” switches are more practical
and more reliable when released for activating the saber. Other switches might
simply have an “inverted” logic (normally closed contact). When
switch
is set
to
1
, the saber lights up when the electrical contact of the switch is closed and
conversely when
switch
is set to 0. If you wish to use a
momentary
switch
for the blade activation, set
switch
to 2.
offp [0-1]
: Anti power off protection (A-POP). To avoid accidentally
powering off the saber, especially when using a momentary button for
activation, we added a power off protection. When this parameter is set to 1,
the user must press the activation button and confirm with the auxiliary button.
It is not necessary to press both buttons at the same time, keep the activation
switch pressed first, then press the auxiliary switch: the blade goes off.
offd [0-65535]
: Anti power-off delay. An alternative to A-POP™ defining
how long the user must press the activation switch before the blade goes off. A
value of 65535 corresponds to 2min12, which is useful if you just upgraded an
ultrasound saber with a PC and you're feeling some power-off scheme
nostalgia. Values from 70 to 200 (140 to 400 ms) are relevant and very