PRIZM 201640 series Скачать руководство пользователя страница 8

Moog Components Group 

4 Port 10/100/1000 Mbps Ethernet Switch 

February 23, 2009

 

(201640-xxx) 

 

Page  8 of 13 

 

J7 

         Led Status 

GND 

1  o  o  2 

PTC FUSE 

PORT1 LINK 

3  o  o  4 

PORT1 DUPLEX 

PORT2 LINK 

5  o  o  6 

PORT2 DUPLEX 

PORT3 LINK 

7  o  o  8 

PORT3 DUPLEX 

PORT4 LINK 

9  o  o  10 

PORT4 DUPLEX 

FIBER LINK 

11  o  o  12 

FIBER DUPLEX 

PORT1 100 

13  o  o  14 

PORT1 1000 

PORT2 100 

15  o  o  16 

PORT2 1000 

PORT3 100 

17  o  o  18 

PORT3 1000 

PORT4 100 

19  o  o  20 

PORT4 1000 

FIBER SD 

21  o  o  22 

FIBER 1000 

MC RX 

23  o  o  24 

MC TX 

 

 

 

Description of Signal Behavior for the Pins of Connector J7 
 

PIN 

Functional Description 

1 (GND) 

Board GND 

2(PTC FUSE) 

+5VDC from board if fuse F2 is placed. 

3(PORT1 LINK) 

LOW if Port 1 is connected to a valid Ethernet device. 

4(PORT1 DUPLEX) 

LOW if Port 1 is operating in FULL DUPLEX.  Predominately HIGH if Port 1 is 
operating  in  HALF  DUPLEX.    In  half  duplex  mode,  the  pin  will  go  LOW 
temporarily to indicate COLLISIONS on PORT 1. 

5(PORT2 LINK) 

LOW if Port 2 is connected to a valid Ethernet device. 

6(PORT2 DUPLEX) 

LOW if Port 2 is operating in FULL DUPLEX.  Predominately HIGH if Port 2 is 
operating  in  HALF  DUPLEX.    In  half  duplex  mode,  the  pin  will  go  LOW 
temporarily to indicate COLLISIONS on PORT 2. 

7(PORT3 LINK) 

LOW if Port 3 is connected to a valid Ethernet device. 

8(PORT3 DUPLEX) 

LOW if Port 3 is operating in FULL DUPLEX.  Predominately HIGH if Port 3 is 
operating  in  HALF  DUPLEX.    In  half  duplex  mode,  the  pin  will  go  LOW 
temporarily to indicate COLLISIONS on PORT 3. 

9(PORT4 LINK) 

LOW if Port 4 is connected to a valid Ethernet device. 

10(PORT4 
DUPLEX) 

LOW if Port 4 is operating in FULL DUPLEX.  Predominately HIGH if Port 4 is 
operating  in  HALF  DUPLEX.    In  half  duplex  mode,  the  pin  will  go  LOW 
temporarily to indicate COLLISIONS on PORT 4. 

Содержание 201640 series

Страница 1: ...l And Troubleshooting Guide February 23 2009 Rev C Moog Components Group Springfield Operations 750 West Sproul Road Springfield PA 19064 E Mail mcg moog com URL www moog com components Tel 610 328 40...

Страница 2: ...Mbps Ethernet Switch Dash Number Definitions 3 1 3 4 Port 10 100 1000 Mbps Ethernet Switch Operation 3 1 4 4 Port 10 100 1000 Mbps Ethernet Switch Indicators and Controls 5 1 5 4 Port 10 100 1000 Mbps...

Страница 3: ...Moog Components Group technical support if you have questions about these or any other features that may be required 1 1 4 Port 10 100 1000 Mbps Ethernet Switch Revision History The 4 Port 10 100 1000...

Страница 4: ...smitter for delivery to the switch at the opposite end of the link The receive portion of the 4 Port 10 100 1000 Mbps Ethernet Switch accepts the optical signal from the remote end of the link and rec...

Страница 5: ...of received optical power from the remote unit D3 Green Green A dual LED located on the top edge of the board next to the optical module The top LED labeled LNK provides an indication that the onboard...

Страница 6: ...D LED This LED will be illuminated GREEN if Port 2 is communicating at 1000Mbps and ORANGE if the port is communicating at 100Mbps If this LED is not illuminated but the LINK LED is lit the port is co...

Страница 7: ...switches on the 4 Port 10 100 1000 Mbps Ethernet Switch CONNECTORS The user accessible connectors on the 4 Port 10 100 1000 Mbps Ethernet Switch are as follows J2 Power Diagnostics RT 1 o o 2 RT GND...

Страница 8: ...UPLEX Predominately HIGH if Port 1 is operating in HALF DUPLEX In half duplex mode the pin will go LOW temporarily to indicate COLLISIONS on PORT 1 5 PORT2 LINK LOW if Port 2 is connected to a valid E...

Страница 9: ...LOW if PORT 2 is operating at 1000Mbps HIGH otherwise 17 PORT3 100 LOW if PORT 3 is operating at 100Mbps HIGH otherwise 18 PORT3 1000 LOW if PORT 3 is operating at 1000Mbps HIGH otherwise 19 PORT4 10...

Страница 10: ...k Lengths up to 20 kilometers with single mode up to 1 kilometers with multimode Onboard Data Channels Number of Data Channels 4 x Gigabit Ethernet Ethernet Data Rates 10 100 or 1000Mbps Off board Dat...

Страница 11: ...e board if 5VDC is not available Verify 3 3VDC across C77 If 3 3V is not available replace the board with a spare If 3 3V is available check the display LED D9 If only the 2 5V Power LED is out Verify...

Страница 12: ...ata bit on the back plane NOTE The diagnostics feature in no way interferes with normal operation of the modem it is not necessary to be running the diagnostics s w for the modem to work 1 9 Communica...

Страница 13: ...Moog Components Group 4 Port 10 100 1000 Mbps Ethernet Switch February 23 2009 201640 xxx Page 13 of 13 Figure 1 Typical Cabling Wiring for Back plane Diagnostics Telemetry...