Moog Components Group
4 Port 10/100/1000 Mbps Ethernet Switch
February 23, 2009
(201640-xxx)
Page 8 of 13
J7
Led Status
GND
1 o o 2
PTC FUSE
PORT1 LINK
3 o o 4
PORT1 DUPLEX
PORT2 LINK
5 o o 6
PORT2 DUPLEX
PORT3 LINK
7 o o 8
PORT3 DUPLEX
PORT4 LINK
9 o o 10
PORT4 DUPLEX
FIBER LINK
11 o o 12
FIBER DUPLEX
PORT1 100
13 o o 14
PORT1 1000
PORT2 100
15 o o 16
PORT2 1000
PORT3 100
17 o o 18
PORT3 1000
PORT4 100
19 o o 20
PORT4 1000
FIBER SD
21 o o 22
FIBER 1000
MC RX
23 o o 24
MC TX
Description of Signal Behavior for the Pins of Connector J7
PIN
Functional Description
1 (GND)
Board GND
2(PTC FUSE)
+5VDC from board if fuse F2 is placed.
3(PORT1 LINK)
LOW if Port 1 is connected to a valid Ethernet device.
4(PORT1 DUPLEX)
LOW if Port 1 is operating in FULL DUPLEX. Predominately HIGH if Port 1 is
operating in HALF DUPLEX. In half duplex mode, the pin will go LOW
temporarily to indicate COLLISIONS on PORT 1.
5(PORT2 LINK)
LOW if Port 2 is connected to a valid Ethernet device.
6(PORT2 DUPLEX)
LOW if Port 2 is operating in FULL DUPLEX. Predominately HIGH if Port 2 is
operating in HALF DUPLEX. In half duplex mode, the pin will go LOW
temporarily to indicate COLLISIONS on PORT 2.
7(PORT3 LINK)
LOW if Port 3 is connected to a valid Ethernet device.
8(PORT3 DUPLEX)
LOW if Port 3 is operating in FULL DUPLEX. Predominately HIGH if Port 3 is
operating in HALF DUPLEX. In half duplex mode, the pin will go LOW
temporarily to indicate COLLISIONS on PORT 3.
9(PORT4 LINK)
LOW if Port 4 is connected to a valid Ethernet device.
10(PORT4
DUPLEX)
LOW if Port 4 is operating in FULL DUPLEX. Predominately HIGH if Port 4 is
operating in HALF DUPLEX. In half duplex mode, the pin will go LOW
temporarily to indicate COLLISIONS on PORT 4.