PRIZM 201640 series Скачать руководство пользователя страница 7

Moog Components Group 

4 Port 10/100/1000 Mbps Ethernet Switch 

February 23, 2009

 

(201640-xxx) 

 

Page  7 of 13 

 

 

FUSE:

  

A 2.6A PTC fuse, F4, protects the +5VDC input to the board. 

 

NOTE:  the  fuse  is  a  positive  temperature  coefficient  self-resetting  fuse  and  does  not  require 
replacement 

 

SWITCHES:

  There are no switches on the 4 Port 10/100/1000 Mbps Ethernet Switch. 

 

CONNECTORS:

   The user accessible connectors on the 4 Port 10/100/1000 Mbps Ethernet Switch are 

as follows: 
 

J2 

Power /Diagnostics 

RT+ 

1  o  o  2 

RT- 

GND 

3  o  o  4 

GND 

GND 

5  o  o  6 

GND 

+5V 

7  o  o  8 

+5V 

+5V 

9  o  o  10 

+5V 

 
 

J4 

RS-485 Serial Diagnostics 

RT+  1 

GND  2 

RT-  3 

 
 

J5 

         Power Entry 

+5VDC  1 

GND  2 

 
 

 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 

Left 

o  o  o  o  o  o  o  o  Right 

J6 

10/100/1000 Ethernet 

Ports 1 - 4 

     Pin #  8  7  6  5  4  3  2  1   

 

 

 

 

 

Pin # 

10/100Mbps 

1000Mbps 

 

TD+ 

A+ 

 

TD- 

A- 

 

RD+ 

B+ 

 

NC 

C+ 

 

NC 

C- 

 

RD- 

B+ 

 

NC 

D+ 

 

NC 

D- 

Содержание 201640 series

Страница 1: ...l And Troubleshooting Guide February 23 2009 Rev C Moog Components Group Springfield Operations 750 West Sproul Road Springfield PA 19064 E Mail mcg moog com URL www moog com components Tel 610 328 40...

Страница 2: ...Mbps Ethernet Switch Dash Number Definitions 3 1 3 4 Port 10 100 1000 Mbps Ethernet Switch Operation 3 1 4 4 Port 10 100 1000 Mbps Ethernet Switch Indicators and Controls 5 1 5 4 Port 10 100 1000 Mbps...

Страница 3: ...Moog Components Group technical support if you have questions about these or any other features that may be required 1 1 4 Port 10 100 1000 Mbps Ethernet Switch Revision History The 4 Port 10 100 1000...

Страница 4: ...smitter for delivery to the switch at the opposite end of the link The receive portion of the 4 Port 10 100 1000 Mbps Ethernet Switch accepts the optical signal from the remote end of the link and rec...

Страница 5: ...of received optical power from the remote unit D3 Green Green A dual LED located on the top edge of the board next to the optical module The top LED labeled LNK provides an indication that the onboard...

Страница 6: ...D LED This LED will be illuminated GREEN if Port 2 is communicating at 1000Mbps and ORANGE if the port is communicating at 100Mbps If this LED is not illuminated but the LINK LED is lit the port is co...

Страница 7: ...switches on the 4 Port 10 100 1000 Mbps Ethernet Switch CONNECTORS The user accessible connectors on the 4 Port 10 100 1000 Mbps Ethernet Switch are as follows J2 Power Diagnostics RT 1 o o 2 RT GND...

Страница 8: ...UPLEX Predominately HIGH if Port 1 is operating in HALF DUPLEX In half duplex mode the pin will go LOW temporarily to indicate COLLISIONS on PORT 1 5 PORT2 LINK LOW if Port 2 is connected to a valid E...

Страница 9: ...LOW if PORT 2 is operating at 1000Mbps HIGH otherwise 17 PORT3 100 LOW if PORT 3 is operating at 100Mbps HIGH otherwise 18 PORT3 1000 LOW if PORT 3 is operating at 1000Mbps HIGH otherwise 19 PORT4 10...

Страница 10: ...k Lengths up to 20 kilometers with single mode up to 1 kilometers with multimode Onboard Data Channels Number of Data Channels 4 x Gigabit Ethernet Ethernet Data Rates 10 100 or 1000Mbps Off board Dat...

Страница 11: ...e board if 5VDC is not available Verify 3 3VDC across C77 If 3 3V is not available replace the board with a spare If 3 3V is available check the display LED D9 If only the 2 5V Power LED is out Verify...

Страница 12: ...ata bit on the back plane NOTE The diagnostics feature in no way interferes with normal operation of the modem it is not necessary to be running the diagnostics s w for the modem to work 1 9 Communica...

Страница 13: ...Moog Components Group 4 Port 10 100 1000 Mbps Ethernet Switch February 23 2009 201640 xxx Page 13 of 13 Figure 1 Typical Cabling Wiring for Back plane Diagnostics Telemetry...

Отзывы: