1.6

  Power Section Testing 

 

Note:    The  +1.2V  Power  LED  (D1)  is  not  functional.    The  board  will  operate  properly  and 
+1.2CVDC is being supplied to the board whether this LED is illuminated or not. 

 
If the +5V Power LED, the +3.3V Power LED, and the +2.5V Power LED are out: 

 

Check for continuity of fuse F1 with an ohmmeter. 

 

Replace fuse if blown.   

 
If only the +5V Power LED is out: 

 

5V DC is present at the source  

 

At J5 if powered off of external power 

 

At J2 if powered off of the daughterboard expansion header. 

 

If +5V is not available replace the board with a spare. 

 

If +5V is available check the display LED (D10). 

 
If only the +3.3V Power LED is out: 

 

5VDC across C79 (replace board if +5VDC is not available) 

 

3.3VDC across C77 

 

If +3.3V is not available replace the board with a spare. 

 

If +3.3V is available check the display LED (D9). 

 
If only the +2.5V Power LED is out: 

 

5VDC across C75 (replace board if +5VDC is not available) 

 

2.5VDC across C65 

 

If +2.5V is not available replace the board with a spare. 

 

If +2.5V is available check the display LED (D7). 

 
 

1.7

  Optical Section Testing 

 
If the FIBER LED, (bottom LED of D2) is off or flickering, one or more of the following conditions is 
likely: 

 

The fiber is broken or damaged. 

 

The optical transceiver module is defective.  

 

Excessive light loss (low received optical power) is being experienced.  

 

The 4 Port 10/100/1000Mbps Ethernet Switch (not the optical transceiver module) is 
malfunctioning. 

 

There is not enough attenuation in the optical link and the receiver is saturating. 

 

Check  the  optical  level  with  an  optical  power  meter  and  inspect  all  fiber  optic  connections 
including WDMs and slip rings. 

 

Содержание 201640 series

Страница 1: ...l And Troubleshooting Guide February 23 2009 Rev C Moog Components Group Springfield Operations 750 West Sproul Road Springfield PA 19064 E Mail mcg moog com URL www moog com components Tel 610 328 40...

Страница 2: ...Mbps Ethernet Switch Dash Number Definitions 3 1 3 4 Port 10 100 1000 Mbps Ethernet Switch Operation 3 1 4 4 Port 10 100 1000 Mbps Ethernet Switch Indicators and Controls 5 1 5 4 Port 10 100 1000 Mbps...

Страница 3: ...Moog Components Group technical support if you have questions about these or any other features that may be required 1 1 4 Port 10 100 1000 Mbps Ethernet Switch Revision History The 4 Port 10 100 1000...

Страница 4: ...smitter for delivery to the switch at the opposite end of the link The receive portion of the 4 Port 10 100 1000 Mbps Ethernet Switch accepts the optical signal from the remote end of the link and rec...

Страница 5: ...of received optical power from the remote unit D3 Green Green A dual LED located on the top edge of the board next to the optical module The top LED labeled LNK provides an indication that the onboard...

Страница 6: ...D LED This LED will be illuminated GREEN if Port 2 is communicating at 1000Mbps and ORANGE if the port is communicating at 100Mbps If this LED is not illuminated but the LINK LED is lit the port is co...

Страница 7: ...switches on the 4 Port 10 100 1000 Mbps Ethernet Switch CONNECTORS The user accessible connectors on the 4 Port 10 100 1000 Mbps Ethernet Switch are as follows J2 Power Diagnostics RT 1 o o 2 RT GND...

Страница 8: ...UPLEX Predominately HIGH if Port 1 is operating in HALF DUPLEX In half duplex mode the pin will go LOW temporarily to indicate COLLISIONS on PORT 1 5 PORT2 LINK LOW if Port 2 is connected to a valid E...

Страница 9: ...LOW if PORT 2 is operating at 1000Mbps HIGH otherwise 17 PORT3 100 LOW if PORT 3 is operating at 100Mbps HIGH otherwise 18 PORT3 1000 LOW if PORT 3 is operating at 1000Mbps HIGH otherwise 19 PORT4 10...

Страница 10: ...k Lengths up to 20 kilometers with single mode up to 1 kilometers with multimode Onboard Data Channels Number of Data Channels 4 x Gigabit Ethernet Ethernet Data Rates 10 100 or 1000Mbps Off board Dat...

Страница 11: ...e board if 5VDC is not available Verify 3 3VDC across C77 If 3 3V is not available replace the board with a spare If 3 3V is available check the display LED D9 If only the 2 5V Power LED is out Verify...

Страница 12: ...ata bit on the back plane NOTE The diagnostics feature in no way interferes with normal operation of the modem it is not necessary to be running the diagnostics s w for the modem to work 1 9 Communica...

Страница 13: ...Moog Components Group 4 Port 10 100 1000 Mbps Ethernet Switch February 23 2009 201640 xxx Page 13 of 13 Figure 1 Typical Cabling Wiring for Back plane Diagnostics Telemetry...

Отзывы: