Prio Expert P500 Скачать руководство пользователя страница 4

4

Direct Flow R.O. Systems Benefits:

Powerful booster pump and high-production R.O. membrane make it possible to build a high-
end direct flow R.O. machine that offers high performance and water quality.

 

Freshness of water filtered in real time. No more stale water from a room temperature tank.

 

Virtually unlimited filtered water production. While conventional systems with tanks are 
limited by the tank capacity, and require prolonged timeouts to refill the tank, a direct flow 
system is limited by the membrane filtration rate only.

 

Better water purification quality due to improved contaminant rejection rate.

 

Typically, up to three times less water is wasted per gallon of filtered water, compared to 
the conventional tank and water storage systems, this is due to the much higher efficiency 
(recovery) rate. Saves you money and Planet Earth’s water resources!

 

Lower cost of ownership due to prolonged service life of pre-filters and membrane, which 
is in turn a result of higher efficiency rate: less water is treated overall by pre-filters and 
the membrane for each gallon of permeate produced. This saves the capacity of pre-filters 
and ensures either less frequent change necessity or better purification.

 

Less number of components leads to better reliability.

How It Works:

The heart of P500 water dispenser is a direct 
flow reverse osmosis multi-stage water filtra-
tion unit. Water supply is done through the in-
let valve, waste water is drained through the 
drain  saddle,  and  filtered  water  delivered  to 
water taps through heater and cooler. Detailed 
connection scheme is shown on the following 
charts.

After installation, you will get clean hot or cold 
water by simply pushing the taps. The pump 
will turn on automatically and will produce fil-
tered water in real time until the heater and 
cooler are full, and then the system will shut 
off  automatically.  Regular  18-seconds  auto-
flush protects membrane from scale and de-
bris build-up.

Содержание Expert P500

Страница 1: ...Prio Expert User s Guide Point of Use Direct Flow Reverse Osmosis Bottleless Hot and Cold Drinking Water Dispenser HOT COLD P500...

Страница 2: ...xtended periods of time when the appliance is not in use Unplug the dispenser from the electrical outlet while servicing the hot cold water unit and changing the membrane or filters Do not use the app...

Страница 3: ...familiarize yourself with the general concept behind the product and main modes of operation Key Features Clean and safe drinking water right in your home No need to transport and dispose of bottled...

Страница 4: ...of ownership due to prolonged service life of pre filters and membrane which is in turn a result of higher efficiency rate less water is treated overall by pre filters and the membrane for each gallo...

Страница 5: ...luded trans former for safe operation Inlet valve An adapter ball valve is included to be installed into the cold water supply line to feed water to the dispenser inlet Drain saddle Fitsastandard1 5 d...

Страница 6: ...0 05 mg L Hydrogen Sulfide 0 00 mg L Maximum supply water TDS 1000 ppm Indoor use only Electrical input AC 220 240V 4 0A 50 60 Hz Maximum length of the line between the inlet valve and the dispenser1...

Страница 7: ...ater tap Do not connect the system to hot water source 2 Depending on your plumbing system and tubing path you may need to use tools like vari able speed drill drill bits screw driver wrench etc You m...

Страница 8: ...ater tap Drain spout 1 2 3 5 6 7 11 10 1 inlet valve 2 low pressure switch 3 solenoid valve 4 pump 5 check valve 6 ush valve 7 drain saddle 8 oat level switch 9 cooler 10 heater 11 optional check valv...

Страница 9: ...three included threaded adapters to make different connection con figurations see chart for details To Connect the tubing to a fitting 1 Remove the lock if present not present in self locking fittings...

Страница 10: ...ouling It s recommended to install optional check valve on the drainage line It works as a sewer backup valve in this case 3 Remove gags and connect tubes as follows See the connection chart for detai...

Страница 11: ...nd cooler become full pump shuts off turn on heater and cooler your dispenser is ready for use Please note that after initial installation or changing the filters or membrane air contained in the new...

Страница 12: ...risk of water leakage or flooding and to ensure optimal R O system performance Change the disposable pre filters every 6 months or sooner if you observe a noticeable reduc tion in water flow rate Chan...

Страница 13: ...back one filter at a time one after another Do not remove all filters at once to avoid mixing up the tubes To change membrane and post filter it is nessesary to remove supporting bracket For this dis...

Страница 14: ...ecommended to perform the cleaning desinfection procedure every 3 6 months Note It may be needed to perform the cleaning more often if cooler and or heater are turned off for a sufficiant periods of t...

Страница 15: ...ll be no disinfectant smell from the water drain water both from the taps and from the drain spout 4 Dispenser outer cleaning take off the dip tray wash both the tray and the screen if present and rin...

Страница 16: ...logo are the trademarks of DWT Deutsche Wassertechnologien GmbH Germany As used herein denotes registered trademark status in Germany only Copyright DWT Deutsche Wassertechnologien GmbH Germany 2014 2...

Отзывы: