![Prio Expert P500 Скачать руководство пользователя страница 14](http://html1.mh-extra.com/html/prio/expert-p500/expert-p500_user-manual_1603373014.webp)
14
Note: For a pre- or post-filter you only need to connect its inlet and outlet. For the membrane
you have to connect the third outlet – to the waste water line. This outlet is located off the
center of the membrane housing. Elbow check valve fitting (with the arrow) has to be con-
nected to the central (permeate) outlet of the membrane housing.
After you finished changing filters or the membrane follow the “initial washing” procedure as
described above. With initial operation, check for leaks. If a leak is observed, verify that the
tube or branch pipe of the filter/membrane housing is pushed into the quick fitting far enough
to seal the tube against the O-ring and that the tubing was cut at 90
o
.
Cleaning & Disinfection
R.O. filtration system removes almost all bacteria and viruses from the water. However, sec-
ondary water pollution is possible at room temperature. It is recommended to perform the
cleaning & desinfection procedure every 3-6 months.
Note: It may be needed to perform the cleaning more often if cooler and/or heater are turned
off for a sufficiant periods of time.
Cleaning & Disinfection Steps:
1. Prepare disinfection agent (bleach solution, vinegar, citric acid or other suitable disinfec-
tion agent).
Use personal protection equipment like goggles and gloves when working with disinfection
agent.
2. Dispenser inner cleaning:
You may need tools like screwdriver or others.
■
switch off heater and cooler
■
shut off the inlet valve
■
unplug the dispenser from the electrical outlet
■
wait for about 30 minutes until heater and cooler come to room temperature
■
take off the dispenser’s top cover unscrewing two screws on the back; pay attention to
wires connected to switches
■
take off cooler tank lid; pay attention to tube and wires connected to the lid
■
pour disinfectant into the cooler tank
■
put back cooler lid and top cover; wait for 15-30 minutes
■
drain water from hot and cold water taps until disinfectant smell appears
■
wait for 2-4 hours.