SYMPTOM

POSSIBLE CAUSE

CHECK

REMEDY

Buns are not toasted 
or product is not dark 
enough.

Toaster settings are 
incorrect.

1. Check heater temperature.

2. Change compression settings. If both crowns and 

heels are light, increase compression setting (the 
higher the compression setting, the greater the 
compression).

3. If only one side is light, adjust the compression 

wall by removing the cotter pin and adding 
washers to move the wall to the appropriate 
position. Replace cotter pin.

Heater or relay is not 
functioning.

1. Turn power off and allow the toaster to cool.

2. Carefully remove the side panels in order to view 

the heater relays.

NOTE: There are two control panels on the front of 
the unit. The yellow control panel on the left controls 
the heaters for the front chamber. The green control 
panel on the right controls the heaters for the rear 
chamber and the buffered bun landing zone.

3. Turn unit ON and immediately press and hold the 

PRINCE CASTLE Logo button, the 
INFORMATION button, and the PRODUCT 
button. Hold these buttons until the display reads: 
“Heater Test”.

4. Press the INFORMATION button.

5. The LED on relay 1 should begin blinking and 

corresponding heater should begin to heat. Verify 
that heat is being generated by the heater.

6. Press the down arrow to move relay 2 and heater 

2. Verify that the relay is operating correctly. The 
display will read the current temperature for this 
heater. Verify that heat is generated by the heater 
and that the display temperature increases by at 
least 5 degrees. Press the down arrow to move to 
the next relay and heater.

NOTE: Heaters 1 and 5 are IR heaters and do not 
have a temperature probe. Therefore, the display will 
not show a temperature setting for these heaters, 
only for 2, 3, 4 and 6.

7. Repeat each of these steps for the remaining 

relays and heaters.

8. If necessary, repeat these steps for the other 

toaster chamber.

Heater configuration is:

1. If relay LEDs do not light 

up, verify that relay is 
receiving voltage from 
main PCB. If it is 
receiving voltage, replace 
relay.

2. Verify that relay is 

sending voltage to 
heater. When LED is on, 
voltage across the output 
terminals should be 
minimal. When LED is 
not on, voltage should be 
at least 208V.

3. If heater is receiving 

voltage, but does not 
generate heat, replace 
heater.

5

4

3

2

1

6

Содержание 340-TCE

Страница 1: ...s this warranty and all work must be performed by an authorized Prince Castle Service Agent All labor shall be performed during regular work hours Overtime premium will not be covered Travel charges a...

Страница 2: ...at 1 800 722 7853 or 630 462 8800 to arrange for a replacement unit 1 NOTE When installing this unit the ambient temperature at the mounting site should not exceed 37 8 C 100 F Your toaster may consis...

Страница 3: ...in position NOTE If yours is a single unit proceed to Step 10 Mounting Holes Align BBLZ Pushed Back into Position 5 A On the rear chamber push the bun chute into the toaster from the back toward the f...

Страница 4: ...sitioned together operate as one toaster Each chamber has its own power switch and Control Panel A Turn the On Off switch es located below the control panel on the side of the unit s to ON After 20 se...

Страница 5: ...prep table Load the buns so that the cut side makes contact with the grey platen cut side in There is a separate slot for the club flatbread section that allows toasting on both sides B Press START bu...

Страница 6: ...6 EN Universal Rapid Toaster 340 TCE Loading Diagram Radiant Heater Radiant Heater Cut Side Out Cut Side Out Radiant Heater Radiant Heater Cut Side Out Cut Side Out Crown Cut Side In Heel Cut Side In...

Страница 7: ...eels When Bagels are to be toasted change one chamber to BAGEL and begin the toasting process 15 minutes before changeover convert one chamber to BUNS REGULAR MENU Bun Loading Unlike other rapid toast...

Страница 8: ...ODUCT Button 2 I INFORMATION Button and UP and DOWN Scroll Buttons While holding the INFORMATION button press the UP and DOWN scroll buttons to view the settings and actual readings Toast Power operat...

Страница 9: ...lity change only the Toast Time settings For minor adjustments to the toast quality use the LIGHT DARK buttons INFORMATION Button UP and DOWN Scroll Buttons 2 Cleaning This unit is not watertight Do n...

Страница 10: ...ion of the platen and both sides of the club platen Add more High Temperature Grill Cleaning Solution to the URT Cleaning Tool as necessary C Place a sanitized cloth at the end of the Cleaning Tool an...

Страница 11: ...in blinking and corresponding heater should begin to heat Verify that heat is being generated by the heater 6 Press the down arrow to move to relay 2 and heater 2 Verify that the relay is operating Th...

Страница 12: ...l an appropriate combination is reached Relay is shorted Remove side panel to view relay When the unit is not calling for heat the LED on the relay should not be lit Measure the voltage across the out...

Страница 13: ...he PRODUCT button Hold these buttons until the display reads Heater Test 4 Press the INFORMATION button 5 The LED on relay 1 should begin blinking and corresponding heater should begin to heat Verify...

Страница 14: ...ace temperature probe Relay is shorted Remove side panel to view relay When the unit is not calling for heat the LED on the relay should not be lit Measure the voltage across the output terminals of t...

Страница 15: ...e encoder 6 Use the UP arrow button scroll to Volume Level 7 Press both the right and left arrows at the same time The display will change to Set Home Switch 8 Locate the two set screws on the collar...

Страница 16: ...Printed in USA 3 06 2006 16 340 506 EN Universal Rapid Toaster 340 TCE Exploded View and Parts List...

Страница 17: ...340 506 EN 17 Printed in USA 3 06 2006 Universal Rapid Toaster 340 TCE Wiring Diagram...

Страница 18: ...355 East Kehoe Blvd Carol Stream IL 60188 USA Telephone 630 462 8800 Fax 630 462 1460 Toll Free 1 800 PCASTLE www princecastle com Printed in 3 06 Prince Castle Inc...

Отзывы: