6.2 Tips for maintenance and safe control
The manufacturing company suggests:
•
Quick daily optical control of the ironing table (locate loose wires etc.) and an optical
control of each part inside the ironing table every 3 month.
In case of a fault or need of repair/maintenance of the whole or part of the ironing table, please
contact the manufacturer or an authorized representative.
7.
Troubleshooting
For the instructions mentioned in the current section please see the
drawing
of the spare parts
of the machine on page 10.
7.1 The vacuum does not function properly
•
Check if there is sufficient power supply.
•
Check if the power supply cable
No 33
has for some reason cut off.
•
Check the circuit breaker F3 2.5A located inside the circuit board.
•
Check if the pedal button is for some reason faulty.
•
Check if motor
No 01
is for some reason damaged.
•
Check the relay
No 36
.
•
Check electric board
No 37
.
7.2
The blowing of air does not function
•
Check if the pedal button
No 15
is for any reason is damaged.
•
Check electric board
No 37
.
•
Check the relay
No 36
.
•
Check the motor
No 1.
7.3
The heating of the working surface is not activated
•
Check if the safety thermostat
No 75
is defective. Replace it.
•
Check if the thermostat
No 76
is defective. Replace it.
•
Check if the electrical impedance
No 116
is burned out. Replace it.
•
Check if the switch
No 50
is faulty. Replace it.
•
Check the power supply cable and power plug on the board surface (
No 71
).
7.4 Ironing buck heating system cannot be activated
•
Check the power supply cable and power plug on the buck.
•
Check the heating switch
No 51
of the buck.
•
Check the electrical impedance of the buck.
7.5 During use the device produces loud noise
•
Check if the motor bearings have been outworn. Replace them.
•
Check the impeller to ensure there is no dust or fuzz that could cause its vibration.