To replace the batteries:

1.  Remove the battery box from the Go-Chair.
2.  Turn the pack upside down.
3.  Remove all screws that hold the battery box 

halves together. 

See fi gure 17

.

4.  Flip the battery box back over so the handle is 

up and remove the lid.

5. Remove the red (+) positive and black (-) 

negative battery cables from each battery.

6.  Unfasten the hook and loop straps from both 

batteries.

7.  Remove the batteries.
8.  Put the new batteries back into the battery box 

(battery terminals up and facing toward the 
center of the powerchair).

9.  Fasten the hook and loop straps around both 

batteries.

10. Reconnect the two (2) battery cables to the 

battery terminals. Make sure the red cable is 
connected to the positive (+) terminal and the 
black cable is connected to the negative (-) 
terminal.

11. Replace the lid and carefully fl ip the battery box 

over so the handle is down.

12. Replace and tighten all the screws that hold the 

battery box together.

13. Reinstall the battery box back onto the Go-Chair.

Figure 17. Go-Chair Battery Box

Battery Replacement

A battery wiring diagram is printed on a decal located inside the battery box. See the specifi cations table 
for correct battery specifi cations.

MANDATORY! Battery posts, terminals, and related accessories contain lead 

and lead compounds. Wear goggles and gloves when handling batteries and 

wash hands after handling.

WARNING! The batteries in your travel chair should only be serviced or 

replaced by an authorized Pride Provider or a qualifi ed technician.

WARNING! Do not replace the batteries when the seat is occupied.

WARNING! Travel chair batteries are heavy. See specifi cations table. If you 

are unable to lift that much weight, be sure to get help. Use proper lifting 

techniques and avoid lifting beyond your capacity.

WARNING! Do not mix old and new batteries. Always replace both batteries 

at the same time.

PROHIBITED! Keep tools and other metal objects away from the battery 

terminals. Contact with tools can cause electrical shock.

You may need the following to change your batteries:

 

metric/standard socket set and ratchet

 

adjustable wrench

 

screwdriver

Identifi cation Key

1. Top Battery Box Cover
2. Batteries
3. Charger Port
4. Bottom Battery Box Cover
5. Circuit Breaker

1

2

2

3

5

4

Содержание Go-Chair

Страница 1: ...k Australia 20 24 Apollo Drive Hallam Victoria 3803 www pridemobility com au New Zealand 38 Lansford Crescent Avondale Auckland New Zealand 1007 www pridemobility co nz Italy Via del Progresso ang Via...

Страница 2: ...ment damage On the product this icon is represented as a black symbol with a red circle and red slash INTENDED USE The intended use of the Pride Mobility Products device is to provide mobility to pers...

Страница 3: ...3 Introduction 4 Safety 5 Your Go Chair 7 Assembly Disassembly 10 Comfort Adjustments 13 Batteries and Charging 17 Care and Maintenance 23 Table of Contents...

Страница 4: ...re additional assistance for setup or operation please contact your authorized Pride Provider Failure to follow the instructions in this manual and those located on your travel chair can lead to perso...

Страница 5: ...is included with your travel chair Please become familiar with all the warnings and safety information found in the Consumer Safety Guide Read and follow the information in the owner s manual Locked a...

Страница 6: ...attendant can be defined as a family member or care professional specially trained in assisting a Go Chair user in various daily living activities As you begin using your Go Chair during daily activit...

Страница 7: ...r base assembly includes the two motors two drive wheels two caster wheels two anti tip wheels two batteries and a foot platform See figures 1 and 2 Figure 1 The Go Chair Your Go Chair Identification...

Страница 8: ...ries when the battery box is removed from the power base See Batteries and Charging Main Circuit Breaker The main circuit breaker is a safety feature built into your Go Chair When the batteries and th...

Страница 9: ...e controller The error message should be cleared If not contact an authorized Pride Provider To engage or disengage the drive system 1 Locate the levers on the rear section of the power base See figur...

Страница 10: ...nstallation and adjustment and foot platform adjustment NOTE Any nylon insert lock nut removed during the disassembly or adjustment of the travel chair must be replaced with a new nut Nylon insert loc...

Страница 11: ...ss to prevent the harness from getting caught in the drive tires pinched in the seat frame or damaged when passing through doorways Disassembly The Go Chair disassembles into five components the seat...

Страница 12: ...he lower frame tube lower the front section and pivot the rear section simultaneously This will engage the frame lock up automatically See figure 7 3 Reinstall the battery pack 4 Reinstall the seat an...

Страница 13: ...and ratchet adjustable wrench metric standard hex key set thread lock Seat Height Adjustment You can adjust the seat to two different heights in 1 in 2 5 cm increments Seat height adjustment requires...

Страница 14: ...n 3 Slide the armrests in or out to the desired width 4 Tighten the knobs and reinsert detent pin Foot Platform Angle Adjustment You can adjust the angle of the foot platform See figure 10 To adjust t...

Страница 15: ...1 Lift up slightly on the latch on the side of the under seat storage bin See figure 12 and swing the under seat storage bin out and away from the travel chair 2 To close the under seat storage bin pu...

Страница 16: ...DATORY Inspect the positioning belt for loose parts or damage including tears worn spots bent hardware damaged latch mechanisms dirt or debris before each use of the travel chair If you discover a pro...

Страница 17: ...e electrical hazard If necessary properly install an approved 3 pronged adapter to an electrical outlet having 2 pronged plug access PROHIBITED Never use an extension lead to plug in your battery char...

Страница 18: ...on charging in progress and charging complete If the LED does not indicate that charging is completedwithin24hours unplugthe charger from the outlet and contact your authorized Pride Provider Refer t...

Страница 19: ...ATTERY BOX GRASP THE BATTERY BOX HANDLE AND LIFT UP TO DISENGAGE THE BOX FROM THE POWER BASE 2 TILT THE BATTERY BOX FORWARD SLIGHTLY 3 LIFT THE BATTERY BOX AWAY FROM THE POWER BASE 4 TO INSTALL THE BA...

Страница 20: ...You should use the charger supplied with the Go Chair It is the safest most efficient tool to charge the batteries We do not recommend using other types of chargers e g an automotive battery charger N...

Страница 21: ...Deep cycle batteries are specifically designed to provide power drain down their charge and then accept a relatively quick recharge AGM batteries should be charged as often as possible They do not ha...

Страница 22: ...or frozen battery should be warmed for several days prior to recharging What about public transportation AGM and Gel Cell batteries are designed for application in travel chairs and other mobility ve...

Страница 23: ...any inconsistencies are found take your Go Chair to an authorized Pride Provider Travel chairs that are frequently exposed to sources of water such as incontinence should be inspected often for corros...

Страница 24: ...inspect the controller from the power base Look for corrosion Contact an authorized Pride Provider if necessary Ensure that all parts of the controller system are securely fastened to your Go Chair Do...

Страница 25: ...ory regulations Contact your local waste disposal agency or authorized Pride Provider for information on proper disposal of travel chair packaging metal frame components plastic components electronics...

Страница 26: ...letely or it may explode To change the wheel 1 Turn off the power to the controller 2 Set the Go Chair up on blocks 3 Remove the drive wheel nut and washer from the axle See figure 16 4 Pull the wheel...

Страница 27: ...Box Battery Replacement A battery wiring diagram is printed on a decal located inside the battery box See the specifications table for correct battery specifications MANDATORY Battery posts terminals...

Страница 28: ...ot move Loose seat or seating components Corrective Maintenance If the battery condition meter does not light up when you turn on the power Check the harness connections Make sure they are tight Check...