![PRG Bad Boy Spot Luminaire Скачать руководство пользователя страница 80](http://html1.mh-extra.com/html/prg/bad-boy-spot-luminaire/bad-boy-spot-luminaire_service-manual_1599738080.webp)
72
BAD BOY
®
SPOT LUMINAIRE FIELD SERVICE MANUAL
Replacing the Interface/LVS Module
Parts:
23.9812.0812
1 EA
ASSY, INTERFACE/LVS MODULE
Tools:
#2 Philips screwdriver
WARNING:
Remove power from luminaire before performing any maintenance procedures.
To replace the Interface/LVS Module:
Step
1. Remove power from luminaire and allow components to cool for at least 5 minutes.
Step
2. Remove Intake Cover. (Refer to
"Removing the Enclosure Covers"
on page 32.)
Step
3. At Interface/LVS Module, remove four 10-32 x 3/8" PPB SEMS screws (
Figure 3-35
).
Step
4. At left side of Interface/LVS Module, disconnect the following wiring:
a.
Fan cable.
b.
APS Control Line cable.
c.
Neutral (white) cable.
d.
Line (black) cable.
e.
Ground cable.
Step
5. At right side of Interface/LVS Module, disconnect the following wiring:
a.
Fan cable.
b.
CAN Bus cable.
c.
Power cables (red and black).
Step
6. Remove Interface/LVS Module from enclosure.
Note:
The battery pack cable is intentionally NOT connected. Do not re-connect.
Step
7. Replace Interface/LVS Module by doing steps in reverse.
Do not connect battery pack cable. Leave this
cable disconnected.
Содержание Bad Boy Spot Luminaire
Страница 1: ...SOFTWARE VERSION 1 6 WWW PRG COM BAD BOY SPOT LUMINAIRE FIELD SERVICE MANUAL...
Страница 11: ...1 DESCRIPTION This chapter contains an overview of luminaire features and components FEATURES COMPONENTS...
Страница 20: ...12 BAD BOY SPOT LUMINAIRE FIELD SERVICE MANUAL Notes...
Страница 34: ...26 BAD BOY SPOT LUMINAIRE FIELD SERVICE MANUAL Notes...
Страница 102: ...94 BAD BOY SPOT LUMINAIRE FIELD SERVICE MANUAL Notes...
Страница 103: ...A TECHNICAL SPECIFICATIONS BAD BOY SPOT LUMINAIRE BAD BOY ROAD CASE AC LINE CURRENT POWER VS VOLTAGE...
Страница 114: ...Bad Boy Spot Luminaire Field Service Manual Version as of November 10 2010 PRG part number 02 9812 0005 C...
Страница 115: ...Production Resource Group Dallas Office 8617 Ambassador Row Suite 120 Dallas Texas 75247 www prg com...