BAD BOY
®
SPOT LUMINAIRE FIELD SERVICE MANUAL
Fan/Cooling Issues
Solution
: Ensure Diffuser Sensor Cable is properly seated.
Solution
: Replace Diffuser Sensor PCB...
page 58
A mechanism motor appears to have no power during calibration or operation
Details
: On each of the three Wheel Controller PCB’s there are four (4) motor drivers. There is a 2 Amp Timed (Slo-Blow) Fuse
to protect each of the four drivers. They provide power for the motors. The silkscreen on the Motherboard PCB has each
mechanism identified near the driver for each of the three Wheel Controller PCBs.
Procedure
: If during calibration or operation, you observe a mechanism servo motor or stepper motor that appears to have no
power, locate the driver for that motor. Verify all cables are installed properly. With power off, visually inspect the driver for
damage. If the driver chip has visible damage, then replace the driver’s PCB. If not, carefully remove the fuse. Check for
continuity to determine if the fuse is open. If the fuse has blown, then inspect the mechanism for shorts or other problems.
Replace any blown fuses and recalibrate the fixture.
Solution
: Replace 2A Fuse...
page 68
Tip Pinch Fan is buzzing or...
"Pinch Fan Err" is displayed in Status Log
Details
: If the fan is buzzing, it is an indication that it is starting to fail. If it stops turning, the lamp will douse and the Status Log
will display "Pinch Fan Err."
Solution
: Replace Tip Pinch Fan...
page 65
Main Head Fan is buzzing or...
"Main Fan Err" is displayed in Status Log
Details
: If the fan is buzzing, it is an indication that it is starting to fail. If it stops turning, the lamp will douse and the Status log
will display "Main Fan Err."
Solution
: Replace Main Head Fan...
page 62
Содержание Bad Boy Spot Luminaire
Страница 1: ...SOFTWARE VERSION 1 6 WWW PRG COM BAD BOY SPOT LUMINAIRE FIELD SERVICE MANUAL...
Страница 11: ...1 DESCRIPTION This chapter contains an overview of luminaire features and components FEATURES COMPONENTS...
Страница 20: ...12 BAD BOY SPOT LUMINAIRE FIELD SERVICE MANUAL Notes...
Страница 34: ...26 BAD BOY SPOT LUMINAIRE FIELD SERVICE MANUAL Notes...
Страница 102: ...94 BAD BOY SPOT LUMINAIRE FIELD SERVICE MANUAL Notes...
Страница 103: ...A TECHNICAL SPECIFICATIONS BAD BOY SPOT LUMINAIRE BAD BOY ROAD CASE AC LINE CURRENT POWER VS VOLTAGE...
Страница 114: ...Bad Boy Spot Luminaire Field Service Manual Version as of November 10 2010 PRG part number 02 9812 0005 C...
Страница 115: ...Production Resource Group Dallas Office 8617 Ambassador Row Suite 120 Dallas Texas 75247 www prg com...