![PRG Bad Boy Spot Luminaire Скачать руководство пользователя страница 111](http://html1.mh-extra.com/html/prg/bad-boy-spot-luminaire/bad-boy-spot-luminaire_service-manual_1599738111.webp)
BAD BOY
®
SPOT LUMINAIRE FIELD SERVICE MANUAL
103
Wide Zoom
130000
120000
110000
100000
90000
80000
70000
60000
50000
40000
30000
20000
10000
0
30.0
20.0
10.0
0.0
-10.0
-20.0
-30.0
Iris Full Open
56º Full Angle
50,000 beam Lumens
Throw Dist (Ft)
20
30
50
75
100
Beam Dia. (Ft)
21.3
31.9
53.2
79.7
106.3
Illuminance (fc)
312
139
50
22
12
Throw Dist (m)
5
10
20
25
30
Beam Dia. (m)
5.3
10.6
21.3
26.6
31.9
Illuminance (lux)
5000
1250
312
200
139
Multiply throw distance by Tn to find beam diameter.
Divide cd (candela) by distance squared to find center beam illuminance.
Dist. in Ft. = foot candles
Dist. in meters = lux
Degrees
Tn = 1.06
cd = 125,000
Candela
Lamp Power = 1400 Watts
Содержание Bad Boy Spot Luminaire
Страница 1: ...SOFTWARE VERSION 1 6 WWW PRG COM BAD BOY SPOT LUMINAIRE FIELD SERVICE MANUAL...
Страница 11: ...1 DESCRIPTION This chapter contains an overview of luminaire features and components FEATURES COMPONENTS...
Страница 20: ...12 BAD BOY SPOT LUMINAIRE FIELD SERVICE MANUAL Notes...
Страница 34: ...26 BAD BOY SPOT LUMINAIRE FIELD SERVICE MANUAL Notes...
Страница 102: ...94 BAD BOY SPOT LUMINAIRE FIELD SERVICE MANUAL Notes...
Страница 103: ...A TECHNICAL SPECIFICATIONS BAD BOY SPOT LUMINAIRE BAD BOY ROAD CASE AC LINE CURRENT POWER VS VOLTAGE...
Страница 114: ...Bad Boy Spot Luminaire Field Service Manual Version as of November 10 2010 PRG part number 02 9812 0005 C...
Страница 115: ...Production Resource Group Dallas Office 8617 Ambassador Row Suite 120 Dallas Texas 75247 www prg com...