![PREVOST X3-45 2017 Скачать руководство пользователя страница 146](http://html1.mh-extra.com/html/prevost/x3-45-2017/x3-45-2017_operators-manual_1599591146.webp)
Starting and Stopping Procedures
PA1627 X3-45 Operator’s Manual
6-4
cables be used correctly and only in
emergencies. To jump start, use another 24 volt
DC, negative grounded, power source. Use only
jumper cables rated at 500 cranking amperes.
DANGER
Injury, explosion, battery acid damage or
charging system overload may result if these
jump starting procedures are not precisely
followed.
WARNING
Wear eye protection and remove rings, metal
jewelry and watches with metal bands.
DANGER
The gases given off by batteries while jump
starting are explosive. Do not smoke near
batteries.
DANGER
The battery could rupture or explode if jump
started when the run-down battery fluid is
frozen or if the battery fluid level is low. Check
condition of run-down battery before
attempting to jump start.
CAUTION
Do not let the two vehicles touch. Keep a
walk-through distance between the two
vehicles. Make sure positive (red) and
negative (black) jumper cable clamps do not
touch.
CAUTION
Never connect the jumper cable to the
negative terminal post of the run-down battery.
WARNING
Before attempting to jump start, make sure the
parking brake is applied and the transmission
is in neutral (N). Turn off all lights, heaters
and other electrical accessories.
CAUTION
Choose a booster vehicle which produces
comparable amperage as your vehicle.
To jump start, proceed as follows:
1. Remove the protective cap from the booster
block terminal located in the R.H. side
engine compartment;
2. Connect one end of the red jumper cable to
the positive (+) post of the booster power
source. If the good battery is in another
vehicle, that vehicle's engine must be shut
OFF
before connecting;
3. Connect the other end of the same red
jumper cable to the positive (+) terminal on
the booster block;
4. Connect one end of the black jumper cable
to the negative (-) post on the booster power
source;
5. Connect the other end of the same black
jumper cable to the negative (-) terminal on
the booster block; If the good battery is in
another vehicle, start that vehicle's engine;
BOOSTER BLOCK LOCATION
06623
6. Let the engine run for a few minutes, then
start the vehicle with the run-down battery;
7. Disconnect the jumper cables in reverse
order given in steps 2 through 5;
8. Install protective cap on the booster block
terminal.
NOTE
Jumper cables must be rated at 500 cranking
amperes. If jumper cable length is 20 feet (6
m) or less, use 2/0 (AWG) gauge wires. If
cable length is between 20 to 30 feet (6 to 9
m), use 3/0 (AWG) gauge wires.
Содержание X3-45 2017
Страница 1: ...OPERATOR S MANUAL X3 45 COACH...
Страница 2: ......
Страница 3: ...COACH MANUFACTURER OPERATOR S MANUAL X3 45 COACH Model Year 2018 PA1627 September 2017...
Страница 8: ......
Страница 12: ......
Страница 28: ...Coach Exterior PA1627 X3 45 Operator s Manual 2 16...
Страница 42: ...Coach Interior PA1627 X3 45 Operator s Manual 3 14...
Страница 100: ...Controls and Instruments PA1627 X3 45 Operator s Manual 4 58...
Страница 186: ...Care and Maintenance PA1627 X3 45 Operator s Manual 8 22...
Страница 189: ...Technical Information PA1627 X3 45 Operator s Manual 9 3 X3 45 OVERALL DIMENSIONS SIDE ELEVATION 18673_1...
Страница 190: ...Technical Information PA1627 X3 45 Operator s Manual 9 4 X3 45 OVERALL DIMENSIONS TOP FRONT AND REAR VIEWS 18674_3...
Страница 200: ...Technical Information PA1627 X3 45 Operator s Manual 9 14...
Страница 202: ......
Страница 206: ...Appendix A PA1627 X3 45 Operator s Manual 4...