Other
Features
PA1627 X3-45 Operator’s Manual
5-31
ACTIVATE STARTING TIME
1. Push menu-button (2) to show menu row at
the top of the display (1).
2. Push selection button (3) or (6) until activate
start sign (B) is blinking.
3. Push enter button (5) to confirm.
4. Push selection button (3) or (6) to browse
starting times (programmed days and times
appear in the display according to the
starting time number).
5. Push enter button (5) to
activate the chosen starting
time: activated starting time
and the chosen number
appear in the display.
DEACTIVATE STARTING TIME
1. Push menu-button (2) to show menu row at
the top of the display (1).
2. Push selection button (3) or (6) until
deactivate start sign (B) is blinking.
3. Push enter button (5) to confirm.
4. Push selection button (3) or (6) until sign
and sign
appear in the display.
5. Push enter button (5) to confirm.
START/STOP INSTANT HEATING
1. To start preheater, push instant heating
button (4) when ignition is ON; sign is
blinking.
2. If the preheater runs well, the sign stops
blinking and appears permanently in the
display.
3. To stop preheater, push instant heating
button (4).
OPERATING TIME WITH INSTANT HEATING
1. Push instant heating button (4) when ignition
is OFF: operating time value appears in the
display.
2. Push selection button (3) or (6) to adjust
operating time.
3. Push enter button (5) to confirm: Sign
appears and the preheater will operate for
the adjusted time.
NOTE
Date and time have to be adjusted in the
settings before using instant heating.
Operational Failure Symptoms via
Fault/Flash code
On preheaters equipped with a fault diagnosis
system using coded light signals, the
equipment-on indicator/operation indicator
flashes. Refer to the following table.
PREHEATER TROUBLESHOOTING AND
MAINTENANCE
Refer to the Spheros manual for more
information.
NOTE
If there are no preheater faults, the preheater
will go through a normal start cycle and
regulate based on thermostat setting.
NOTE
Switch on the preheating system briefly about
once a month, even during the warm season.
CAUTION
When welding on the vehicle, disconnect the
preheater module connector in order to
protect this system from voltage surges.
CAUTION
To avoid running down the batteries, do not
turn on the preheating system for more than
one hour before starting the engine.
WARNING
The preheating system uses the same fuel as
the engine. Do not operate in a building or
Содержание X3-45 2017
Страница 1: ...OPERATOR S MANUAL X3 45 COACH...
Страница 2: ......
Страница 3: ...COACH MANUFACTURER OPERATOR S MANUAL X3 45 COACH Model Year 2018 PA1627 September 2017...
Страница 8: ......
Страница 12: ......
Страница 28: ...Coach Exterior PA1627 X3 45 Operator s Manual 2 16...
Страница 42: ...Coach Interior PA1627 X3 45 Operator s Manual 3 14...
Страница 100: ...Controls and Instruments PA1627 X3 45 Operator s Manual 4 58...
Страница 186: ...Care and Maintenance PA1627 X3 45 Operator s Manual 8 22...
Страница 189: ...Technical Information PA1627 X3 45 Operator s Manual 9 3 X3 45 OVERALL DIMENSIONS SIDE ELEVATION 18673_1...
Страница 190: ...Technical Information PA1627 X3 45 Operator s Manual 9 4 X3 45 OVERALL DIMENSIONS TOP FRONT AND REAR VIEWS 18674_3...
Страница 200: ...Technical Information PA1627 X3 45 Operator s Manual 9 14...
Страница 202: ......
Страница 206: ...Appendix A PA1627 X3 45 Operator s Manual 4...