background image

 

 
 

No. 

Parts Name 

PRF047XW 

PRF071XW/PRF3X-3XT 

Door 

Hinge 

Shelf 

Freezer Cabinet 

Thermostat cover 

Compressor base 

Condensate  Water  Drain 
cap 

Fixing feet 

 
7

Disassembling and replacing of the components: 

When replacing the components, must unplug the unit first, in order to be safety. 

1)

  Replace the thermostat

 

Unscrew  the  fixing  screw  of  the  thermostat  box,  remove  the  thermostat  box,  then 

remove the old thermostat, install the new thermostat with same model, and reinstall back the 

whole thermostat box with same fixing screw. 

2)

Replace the PTC starter and overload protector of the compressor

 

Remove the clamp of the connecting terminal cover of the compressor and the terminal 

cover, toward the vertical direction, remove the broken-down starter or overload protector, install 

back the new starter or overload protector, then fix back the terminal box cover and its clamp. 

3)

Replace the door gasket seal: 

Remove  the  old  door  gasket  seal  from  the  groove  of  the  door  linear,  then  install  the  new 

gasket seal into the four sides of the groove, install it oven as possible, open and close the door 

several times, ensure that the door is sealed. 

4)

Replace the compressor

 

a

First  cut  the welding point of the technical  pipe of the compressor to  discharge the 

refrigerant  inside  the  cooling  system,  then  weld  the  old  point  to  disconnect  the  pipe  to  the 
compressor, remove the compressor to replace with a new one, pay attention to replace with a 
new refrigerant dry filter. 

b

Install the new compressor, weld the high pressure side and low pressure side pipe to 

the  compressor,  check  the  system  leakage,  after  completing  vacuum  the  cooling  system, 
charge the correct amount refrigerant into the system from low pressure side pipe. After this, 
run the unit to check the cooling performance is ok or not, then weld and close the technical 
pipe. 

Содержание PRF047XW

Страница 1: ...Service Manual for Single Door Fridge PREMIUM MODEL PRF047XW PRF071XW PRF3X PRF3XT...

Страница 2: ...ng System Diagram 5 6 Part Lists and explanation 5 7 Disassembling and replacing of the components 6 8 Check the breakdowns of the cooling system 7 9 Table for quick answer for the field problem 9 10...

Страница 3: ...al and simple beautifu recessed handle Recessed door gasket seal easy to be discharged and cleaned Plastic material simple and practically One shelf and one drip tray inside Front Left and right side...

Страница 4: ...t keep the room good air circulation condition When cutting the suction pipe or discharging pipe of the compressor pay attention to the surplus refrigerant and internal pressure in cooling system pipe...

Страница 5: ...ce and assembly must use the multi meter to measure the insulation resistance if it is greater than 1 million ohm then you can plug on the unit 8 Grounding test After maintenance use the multimeter to...

Страница 6: ...sed compressor model 5 Cooling System Diagram Note Arrow direction means the flowing direction of the refrigerant 6 Part Lists and explanation PRF047XW PRF071XW PRF3X PRF3XT Capillary Dry Filter Evapo...

Страница 7: ...starter or overload protector then fix back the terminal box cover and its clamp 3 Replace the door gasket seal Remove the old door gasket seal from the groove of the door linear then install the new...

Страница 8: ...7 8 Check the breakdowns of the cooling system Following the next illustration to check the problem...

Страница 9: ...ter Vacuuming and recharging Leakage check again Big quantity refrigerant air spurt out Cut off the high pressure pipe Normal suction of the comressor low pressure pipe No air suction or weak suction...

Страница 10: ...re vacuum and recharge the refrigerant at last do the leakage detecting again B If big quantity refrigerant spurt out cut off the high pressure pipe to check the suction of the compressor low pressur...

Страница 11: ...ed of the circuit or turn the thermostat to the coldest point the compressor can run Thermostat is breakdown There is sound when turning the knob of the thermostat The knob is broken or is not install...

Страница 12: ...d of refrigerant flowing in cooling system and it leaves oil on the welding point Leakage of refrigerant There is no sound of refrigerant flowing in cooling system and no oil on the welding point Insi...

Страница 13: ...tly The unit is not placed at good position The freezer is inside direct sunshine The unit can not dissipate the heat because sunshine The back of the unit is too close to the wall Too close will affe...

Страница 14: ...stem and control it more strictly Left water quantity control a If the cooling system parts like condenser evaporator compressor or the dry filter etc need to be replaced the replaced parts should be...

Страница 15: ...t condition And ensure to use a little as enough as possible Check the compressor is pressurized or not when opening When storing the R134a refrigerant must keep it sealed and not touch with atmospher...

Страница 16: ...happens again then should service again 12 Maintenance parts list No Parts name PCS unit Note 1 Compressor 1 2 Thermal protector of compressor 1 3 PTC starter 1 4 Feet of compressor 4 5 Refrigerant d...

Отзывы: