runs but 

cooling 

effect is not 

good. 

Thermostat  is  set  at  higher  temperature 
(lower digit)? 

  Set  it  to  lower 
temperature 

There  is  too  more  food  in  cooling 

compartment, too crowded, ensure good 
air circulation inside freezer 

Too more food 

Is  there  high  temperature  food,  like  hot 
soup etc., inside freezer? 

Hot  temperature 
food 

let 

the 

temperature 
inside 

freezer 

cooling 
compartment 
rise. 

Too more times of opening of the door 

It  will  affect  the 
cooling effect 

Leakage 

of 

cooling air 

Check  the  door  gasket  sealing  strip  is 
broken or deforming 

Broken  of  the 
door 

gasket 

sealing strip 

Check the door is warded off by the food 
and the door is closed tightly or not. 

The  door  is  not 
closed tightly 

The  unit  is  not 

placed  at  good 
position 

The freezer is inside direct sunshine   

The  unit  can  not 
dissipate the heat 
because sunshine 

The  back  of  the  unit  is  too  close  to  the 
wall 

Too  close  will 
affect  the  heat 
dissipation 

There is heat source near the unit. 

Over-hot 
environment will 
affect  the  heat 
dissipation 

  (C)

 

Temperature 

is too low 

Abnormal  action 
of thermostat 

Check  the  sensor  head  of  the  thermostat 
is loosing or not 

Incorrect 
temperature 
sensing 

of 

thermostat 

Thermostat is not at good quality 
 

Thermostat 

is 

breakdown 

(D)

 

Water 

condensate 

There 

is 

condensed  water 
on the closure 

The environment is too wet 

The 

relative 

humidity  is  too 
high 

  (E)

 

Leakage   

of 

electricity 

Electrical 

shock 

sense 

on 

the 

enclosure 

Confirm the insulation resistance is lower 
than 1 MΩ by the meg ohm meter 

Insulation  is  not 
good 

Check  the  electrical  parts  of  the  unit  are 
wet 

Insulation  is  not 
good 

Содержание PRF047XW

Страница 1: ...Service Manual for Single Door Fridge PREMIUM MODEL PRF047XW PRF071XW PRF3X PRF3XT...

Страница 2: ...ng System Diagram 5 6 Part Lists and explanation 5 7 Disassembling and replacing of the components 6 8 Check the breakdowns of the cooling system 7 9 Table for quick answer for the field problem 9 10...

Страница 3: ...al and simple beautifu recessed handle Recessed door gasket seal easy to be discharged and cleaned Plastic material simple and practically One shelf and one drip tray inside Front Left and right side...

Страница 4: ...t keep the room good air circulation condition When cutting the suction pipe or discharging pipe of the compressor pay attention to the surplus refrigerant and internal pressure in cooling system pipe...

Страница 5: ...ce and assembly must use the multi meter to measure the insulation resistance if it is greater than 1 million ohm then you can plug on the unit 8 Grounding test After maintenance use the multimeter to...

Страница 6: ...sed compressor model 5 Cooling System Diagram Note Arrow direction means the flowing direction of the refrigerant 6 Part Lists and explanation PRF047XW PRF071XW PRF3X PRF3XT Capillary Dry Filter Evapo...

Страница 7: ...starter or overload protector then fix back the terminal box cover and its clamp 3 Replace the door gasket seal Remove the old door gasket seal from the groove of the door linear then install the new...

Страница 8: ...7 8 Check the breakdowns of the cooling system Following the next illustration to check the problem...

Страница 9: ...ter Vacuuming and recharging Leakage check again Big quantity refrigerant air spurt out Cut off the high pressure pipe Normal suction of the comressor low pressure pipe No air suction or weak suction...

Страница 10: ...re vacuum and recharge the refrigerant at last do the leakage detecting again B If big quantity refrigerant spurt out cut off the high pressure pipe to check the suction of the compressor low pressur...

Страница 11: ...ed of the circuit or turn the thermostat to the coldest point the compressor can run Thermostat is breakdown There is sound when turning the knob of the thermostat The knob is broken or is not install...

Страница 12: ...d of refrigerant flowing in cooling system and it leaves oil on the welding point Leakage of refrigerant There is no sound of refrigerant flowing in cooling system and no oil on the welding point Insi...

Страница 13: ...tly The unit is not placed at good position The freezer is inside direct sunshine The unit can not dissipate the heat because sunshine The back of the unit is too close to the wall Too close will affe...

Страница 14: ...stem and control it more strictly Left water quantity control a If the cooling system parts like condenser evaporator compressor or the dry filter etc need to be replaced the replaced parts should be...

Страница 15: ...t condition And ensure to use a little as enough as possible Check the compressor is pressurized or not when opening When storing the R134a refrigerant must keep it sealed and not touch with atmospher...

Страница 16: ...happens again then should service again 12 Maintenance parts list No Parts name PCS unit Note 1 Compressor 1 2 Thermal protector of compressor 1 3 PTC starter 1 4 Feet of compressor 4 5 Refrigerant d...

Отзывы: