8.2.6 Indoor / outdoor
unit’s communication error diagnosis and solution
Measure Vs, is it positive fluctuation?
(Vs is the voltage between S and N of
outdoor unit. Red pan-S, Black pan-N)
Measure Vs, is it positive fluctuation?
(Vs is the voltage between S and N of
outdoor unit. Red pan-S, Black pan-N)
Yes
Power off, then restart the unit 2 minutes later
Power off, then restart the unit 2 minutes later
No
Replace the outdoor main PCB.
Power on. Is the error
extinguished?
Replace the outdoor main PCB.
Power on. Is the error
extinguished?
Check the outdoor wiring connection
Check the outdoor wiring connection
Replace the indoor main PCB.
Power on. Is the error
extinguished?
Replace the indoor main PCB.
Power on. Is the error
extinguished?
Yes
Replace the outdoor main PCB.
Replace the outdoor main PCB.
No
Replace the indoor main PCB.
Replace the indoor main PCB.
No
Check the indoor wiring connection
Check the indoor wiring connection
Yes
Yes
Check whether reactor
is normal?
Check whether reactor
is normal?
Yes
Replace the reactor
Replace the reactor
No
Содержание PAC1203711
Страница 1: ...Service Manual PAC1203711 PAC1803711 PAC2403711 ...
Страница 9: ...Model L mm R mm H mm Dimension of installation hole mm PAC1203711 100 95 45 65 PAC1803711 110 100 45 ...
Страница 10: ...Model L mm R mm H mm Dimension of installation hole mm PAC2403711 293 163 45 65 H L R ...
Страница 24: ...Use torque wrench to tighten the service port cap to a torque of 18N m Be sure to check for gas leakage ...