T3
Compressor Off
Compressor On
When high condenser temp. T3 is more than setting value, the compressor will stop.
During the protection, the outdoor fan keeps working.
7.4.3 Heating Mode(for heat pump models)
7.4.3.1 Compressor running rules
When indoor room temp.T1 is higher than setting value the compressor and outdoor fan will shut
off.
T1
Off
On
7.4.3.2 Outdoor fan running rules:
The outdoor units have single fan speed. The outdoor fan will run following the compressor except
when AC is in evaporator high temp. protection in heating mode , condenser high temp. protection
in cooling mode ,defrosting mode and the current protection.
7.4.3.3 Indoor fan running rules:
When the compressor is on, the indoor fan can be set to high/med/low/auto. And the anti-cold