7. Electronic function
7.1 Abbreviation
T1: Indoor room temperature
T2: Coil temperature of evaporator
T3: Coil temperature of condenser
T4: Outdoor ambient temperature
T5: Compressor discharge temperature
7.2 Display function
7.2.1 Icon explanation on indoor display board.
ION indication lamp(optional function)
:
This lamp illuminates when Clean Air
feature is activated.
DEFROST indication lamp(For cooling & heating models only):
Lights up
when the air conditioner starts defrosting automatically or when the warm air
control feature is activated in heating operation.
OPERATION indication lamp
:
This lamp illuminates when the air conditioner is in
operation.
TIMER indication lamp
:
Lights up during Timer operation.
Temperature indicator
:
Displays the temperature settings when the air conditioner
is operational. Displays the malfunction code.
Содержание PAC1203711
Страница 1: ...Service Manual PAC1203711 PAC1803711 PAC2403711 ...
Страница 9: ...Model L mm R mm H mm Dimension of installation hole mm PAC1203711 100 95 45 65 PAC1803711 110 100 45 ...
Страница 10: ...Model L mm R mm H mm Dimension of installation hole mm PAC2403711 293 163 45 65 H L R ...
Страница 24: ...Use torque wrench to tighten the service port cap to a torque of 18N m Be sure to check for gas leakage ...