Page 4
Hardness:
Recommended hardness not to exceed 10 grains per gallon, or 170ppm. System will
operate with hardness over 10 grains but the membrane life may be shortened. Addition of a water
softener may lengthen the membrane life.
Installation must comply with state and local plumbing regulations. This system is intended to
be installed on the cold water line only.
1 Tank - White
2 Blue Tube 1/4”
1 RO Module (complete with filters)
1 Green Tube 1/4”
1 Parts Bag
1 Faucet Bag
1 Manual
If any of the items are missing please contact Premier prior to installing.
Tools Recommended For Installation
√
1 1/4" Hole Saw Bit for Faucet opening
√
Round Knock out Punch for Stainless Sinks 1 ¼”
√
Adjustable Wrench
√
Sharp Knife
√
1 / 2" Open End Wrench
√
Phillips Screw Driver
√
Needle Nose Pliers – Adjustable Pliers
√
Electric Drill
√
1/4" & 3/8" Drill Bits
Contents of Reverse Osmosis (RO) System
Copper Tubing:
Reverse Osmosis water should not be run through copper tubing as the purity of
the water will leach copper causing an objectional taste in water and pin holes may form in the tubing.
Premier supplies speciality filters (part number 107008) that can be used if copper tubing follows the
Reverse Osmosis unit. Be sure to follow any state or local regulations during installation.
Operational Parameters
Water Pressure:
The operating water pressure in your home should be tested over a 24 hour
period to attain the maximum pressure. If the incoming water pressure is above 85 psi a pressure
regulator is recommended and if over 100 psi then a pressure regulator is required.
Operating Temperatures:
Maximum 100°F (37.8°C)
Minimum 40°F (4.4°C)
Operating Pressure:
Maximum 85 psi (6.0 kg/cm
2
)
Minimum 40 psi (2.80 kg/cm
2
)
pH Parameters:
Maximum 11
Minimum 2
Iron:
Maximum 0.2 ppm
TDS (Total Dissolved Solids)
< 1800 ppm
Turbidity
< 5 NTU