RECOMMENDED REPLACEMENT PARTS AND CHANGE INTERVALS:
Note: Depending on incoming feed water conditions replacement time frame may vary.
Description
Change time Frame
Cost
Sediment Pre-filter:
#114105
6 Months
$ 9.95
Carbon Pre-filter:
#114106
6 Months
$15.95
Post Carbon filter
#114107
12 Months
$15.50
50 GPD R.O. Membrane:
#114110
2 to 5 years
$99.00
This system has been tested according to ANSI 58 for reduction of the substances listed below. The concentration of the indicated substances in water entering
the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system as specified in ANSI 58. This system has been
tested for the treatment of water containing pentavalent arsenic (also known as As (V), As (+5), or arsenate) at concentrations of 0.30 mg/L or less. This system
reduces pentavalent arsenic, but may not remove other forms of arsenic. This system is to be used on water supplies containing a detectable free chlorine residual
at the system inlet or on water supplies that have been demonstrated to contain only pentavalent arsenic. Treatment with chloramine (combined chlorine) is not
sufficient to ensure complete conversion of trivalent arsenic to pentavalent arsenic, Please see the Arsenic Facts section of the Performance Data Sheet for further
information.
Avg. In.
Avg. Eff.
% Reduction pH
Pressure
Max Eff.
Inf. challenge
Max Allowable
(mg/L)
(mg/L)
mg/L
concentration
concentration
mg/L
mg/L
Arsenic (Pentavalent)
.310
0.001
99.6%
7.24
50psi
0.002
0.30±10%
0.010 mg/L
Barium Reduction
9.2
0.08
99.0%
7.64
50psi
0.12
10.0±10%
2.0
Cadmium Reduction
0.031
0.0004
98.0%
7.49
50psi
0.0008
0.03±10%
0005
Chromium (Hexavalent)
0.30
0.002
99.0%
7.24
50psi
0.004
0.03±10%
0.1
Chromium (Trivalent)
0.30
0.001
99.0%
7.64
50psi
0.002
0.03±10%
0.1
Copper Reduction
3.2
0.02
99.0%
7.40
50psi
0.04
3.0±10%
1.3
Cysts
92,000#/ml
3 #/ml
99.99%
7.44
50psi
18 minimum 50,000/mL
N/A
Fluoride Reduction
8.7
0.19
97.0%
7.24
50psi
0.3
8.0±10%
1.5
Lead Reduction
0.15
0.002
98.8%
7.39
50psi
0.005
0.15±10%
0.0107
Nitrate
27
3.8
86.0%
7.24
50psi
4.3
27.0 ±10%
10.0
Nitrite
3.1
0.41
86.0%
7.24
50psi
0.46
3.0 ±10%
1.0
N Nitrite
30
4.2
86.0%
7.24
50psi
4.8
30.0 ±10%
10.0
Perchlorate
0.14
0.003
97.0%
7.39
50psi
0.005 mg/L
0.10±10%
0.006
Radium 226/228
25pCi/L
5pCi/L
80.0%
7.24
50psi
5pCi/L
25pCiL±10%
5pCiL
Selenium
94.85
<0.2
97.0%
7.24
50psi
<0.2
0.10±10%
0.05
TDS
741
22
97.0%
7.28
50psi
26.0
750±40mg/L
187
Turbidity
11.3
0.1
99.0%
7.43
50psi
0-1
11±1mg/L
0.5NTU
Recovery - 15.77%
Daily Production Rate - 18.43 GPD
Efficiency - 8.82%
Depending on water chemistry, water temperature, and water pressure Premier’s R.O. Systems production and performance will vary.
Efficiency rating means the percentage of the influent water to the system that is available to the user as reverse osmosis treated water under
operating conditions that approximate typical daily usage. Recovery rating means the percentage of the influent water to the membrane portion
of the system that is available to the user as reverse osmosis treated water when the system is operated without a storage tank or when the
storage tank is bypassed. There is an average of 4 gallons of reject water for every 1 gallon of product water produced.
REFER TO OWNER’S INSTALLATION/SERVICE MANUAL FOR FURTHER MAINTENANCE REQUIREMENTS AND WARRANTY
INFORMATION.
Phone: 480-675-7995 Fax: (623) 866-5666 Email: [email protected]
GENERAL USE CONDITIONS:
1. System to be used with municipal or well water sources treated and tested on regular basis to insure bacteriological safe quality. DO NOT use with water that
is microbiologically unsafe or unknown quality without adequate disinfection before and after the system. Systems certified for cyst reduction may be used on
disinfected water that may contain filterable cysts.
2. This system is acceptable for treatment of influent concentrations of no more than 27 mg/L nitrate and 3 mg/L nitrite in combination measured as N and is
certified for nitrite/nitrate reduction only for water supplies with a pressure of 280 kPa (40 psig) or greater. If your water supply is under 40 psi Premier recomends
the use of a RO booster pump for proper operation.
3. Operating Temperature:
Maximum: 100°F (40.5°C)
Minimum: 40° (4.4°)
4. Operating Water Pressure:
Maximum: 85 psi (6.0kg/cm2)
Minimum: 40 psi (2.8kg/cm2)
5. pH
2 to 11
6. Maxiumum Iron present in incoming water supply must be less than 0.2 ppm.
7. Hardness of more than 10 grains per gallon (170 ppm) may reduce RO membrane life expectancy.
8. Recommend TDS (Total Dissolved Solids) not to exceed 1800 ppm.