HOW TO USE
•
Instruction of All Working Modes
•
Manual Mode
Use the Selection Dial to select the icon. The adjust the Time Setting and Speed
Setting. The press Button to start operation. If the user wants to stop the
operation, press the Button again. The product stops running and resumes
Ready Mode.
•
Preset Program Mode
There are 6 preset programs for various food selections. Turn the Selection Dial to
the desired program, the display will show in the format as section 2.6 described.
Finally press the Button to run the selected program (refer to section 2.6).
•
Total Working Time Display
In the Ready Mode, press and hold the Button, and then keep pressing
Button for 5 seconds. The Time Display will show the total accumulated working
time of the motor (unit: in minute) for 3 seconds. Then the product resumes Ready
Mode. The product counts the total working time in seconds, and displays in minutes.
The maximum displayable time is 99999 minutes. The Speed Display represent the
digits in 10000.
e.g total working time is 6528 minutes :
e.g. total working time is 26528 minutes :
•
The Speed Buttons
, Time Buttons
& Pulse Button
light on white light.
Button light on red light in Ready Mode, and green light in
operation. The button selected program flashes during operation, and other icons
light on white light. Buzzer beeps in each pressing of the button.
•
Operation Flow
When the product is energized, it enters Standby Mode (refer to section 1.1)
A. Turn the Selection Dial to select any preset program, the corresponding icon
flashes and the product operate in the selected procedures (refer to section 2.6)
B. In Manual Mode, press
Button to start operation.
During operation, press
Button will stop the operation, and the product resumes
Ready Mode.
•
Rating : Motor rated power is 1400W
•
Other Requirements :
1. Normal working voltage : AC 120V~60Hz (PCBA runs normally in 90V~130V)
2. Normal working humidity : 20% ~ 90%
3. Normal working temperature : -5°C ~ 55°C
4.Storage & transportation temperature of PCB is -20°C ~ 70°C. Working
temperature cannot exceed 55°C. It needs anti-shock protection.
7
Содержание ED-5189PRO
Страница 2: ......
Страница 12: ...P 7 ...
Страница 13: ...P 8 ...
Страница 14: ...P 9 ...
Страница 15: ...P 10 ...
Страница 16: ...P 11 ...
Страница 17: ...P 12 ...
Страница 18: ...P 13 ...
Страница 19: ...P 14 ...
Страница 20: ...P 15 ...
Страница 21: ...P 16 ...
Страница 22: ...P 17 ...
Страница 23: ...P 18 ...