Prem-Air PREMSW Скачать руководство пользователя страница 5

1.5

HANDLING

To avoid any possible damages during transportation the unit is provided with compressor holders
that must be removed before installing the air conditioner (see 2.7).

1.6

PART LIST

1.

FASTENING BRACKET

2.

REMOTE CONTROL

3.

REMOTE CONTROL HOLDER

4.

DRAINAGE PIPE

5

EXTENSION CONDENSATE HOSE

6.

PIPE FASTENING INNER FLANGE

7.

EXTERNAL GRATING

8.

HOT AIR DISCHARGE PIPE (160 mm.)

9.

AIR INTAKE PIPE (150 mm.)

10.

PAPER TEMPLATE FOR WALL DRILLING

11.

KIT OF SCREWS AND CABLE TIE

12.

GRATING FIXING CORD

13.

INSTRUCTION MANUAL

14.

RUBBER PLUG

Any batteries used in the remote control
contain materials, which are hazardous to the
environment.
They must be removed from the remote control
when they reach the end of their life
and disposed of responsibly.

·

Be fully aware of the weight of the unit before attempting to lift it. Take all necessary
precautions to avoid damaging the product or causing personal injury.

·

It is advisable to remove the packing only when the air conditioner has been located in the
point of installation.

·

Carefully remove the adhesive strips positioned on the air conditioner.

·

Packaging components must be disposed correctly and not left within reach of children,
since they are a potential source of danger.

This product has been manufactured to comply
with EEC Directives 73/23/EEC and 89/336/EEC

Waste electrical products should not be
disposed of with household waste.
Please recycle where facilities exist.
Check with your Local Authority or retailer
for recycling advice.

5

Содержание PREMSW

Страница 1: ...High Wall Low Wall Air Conditioner Model PREMSW IMPORTANT SAFETY INSTRUCTIONS PLEASE READ ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OPERATING 1...

Страница 2: ...F AIR PIPES AND GRATINGS 2 6 FITTING THE GRATINGS FASTENING THE BRACKET 2 7 FITTING THE UNIT ON BRACKET 2 8 DRAINAGE LINE 3 1 REMOTE CONTROL 3 2 REMOTE CONTROL FUNCTIONS 3 3 INSTRUCTIONS FOR USE WITH...

Страница 3: ...s equipment must be in accordance with the strict regulation governing the recycling of this product please operate with caution during the disposal Please contact your local authority for regulatory...

Страница 4: ...2 Never place the power cord under a carpet or rug Do not operate the unit in areas where petrol paint or other flammable liquids are used or stored 13 Do not carry out any cleaning or maintenance or...

Страница 5: ...removed from the remote control when they reach the end of their life and disposed of responsibly Be fully aware of the weight of the unit before attempting to lift it Take all necessary precautions...

Страница 6: ...TIONAL FLAP DRAINAGE PIPE SIDE COVER RED LED switched on power supply is connected GREEN LED switched on compressor is on YELLOW LED switched on timer is on BLUE LED switched on night mode is on DISPL...

Страница 7: ...e airflow The unit must be fitted leaving room all around as illustrated in the paper template The wall on which the unit is installed must be sturdy and able to withstand the weight of the unit After...

Страница 8: ...peed Fasten the template to the wall taking care to check the distance From the floor and or ceiling and keep it horizontal by using a spirit level Use a pilot drill to mark the centre of each core ho...

Страница 9: ...he supplied pipes to the correct length The tube diameter is nearly the same as that carried out using the 165 mm nominal diameter core drill therefore you may need to slightly force the introduction...

Страница 10: ...herefore fits on the outside of the air intake tube Insert the supplied cord into the hole Fold the outer grating in half grasping the cord with your free hand Insert your arm inside the pipe with the...

Страница 11: ...an be discarded Lift it up by holding the sides at the bottom and not the front panel Tilt the unit slightly towards you to facilitate the operation of fastening it onto the bracket The unit is provid...

Страница 12: ...with an internal diameter of 16 mm can be fitted if necessary If the line drains into a vessel tank or other recipient this container should not be sealed and the drainpipe should not remain immersed...

Страница 13: ...d while the unit is running In Auto mode the temperature settings are not adjustable see paragraph 3 9 Slide the front panel downwards to display further buttons Timer on Timer off Fan speed x 3 Sleep...

Страница 14: ...he fan speed among high middle low or auto In case AUTO is chosen the fan speed is automatically adjusted to keep it as high as needed to reach the setting temperature Press the button and adjust the...

Страница 15: ...Extract the filters B C from their case Clean the B C filters only with a vacuum cleaner being careful not to damage them Clean the A filter by washing it with warm water max 40 C and mild detergent...

Страница 16: ...Presence of voltage The filter could be dirty Clean it The room temperature is too high Wait until the temperature goes down The temperature is not properly set Check it The grids could be obstructed...

Отзывы: