2.7 FITTING THE UNIT ON BRACKET
After checking again that the fastening bracket is securely fastened to the wall, and that any necessary
preparations for electric connection and condensate drainage have been made, please remove the
compressor holders (remove plastic belt A and unscrew holder B and fasten the air conditioner to its
supporting bracket, A and B can be discarded ).
Lift it up by holding the sides at the bottom and not the front panel
Tilt the unit slightly towards you to facilitate the operation of fastening it onto the bracket. The unit is
provided with an insulated drainage pipe (450mm long), to fit on the pipe that protrudes from the lower
backside of the unit,which is inserted in the drainage hole.
The air conditioner can now be pushed firmly against the wall. Carefully inspect the installation to ensure that
the insulating back panel fits firmly against the wall and there are no fissures at the back of the air
conditioner.