background image

7

8.08

Trim excess LOCK-TAPE Sealant to within
1/8" (3.18 mm) of the End Plate.  DO NOT

STRETCH TAPE DURING TRIMMING PROCESS.

9.00

BONDING AND/OR GROUNDING
CABLES WITH METALLIC COMPO-
NENTS

NOTE:

Installation of bonding and grounding

components may be easier if installed prior to
placing cables into End Plate.

9.01

If cable contains a metallic shield, install

shield connector and/or bonding assembly per
company instructions.  A shield connector is available
separately from PLP under Catalog No. 80803989.

FIGURE 19 -BONDING ASSEMBLY

9.02

After the bond connector is installed on the
cable and the cable placed in the End Plate

next to the appropriate “L” bracket, attach the bond
connector to the “L” bracket through the slot pro-
vided.

9.03

If cable contains a strength member, insert
the strength member into the retainer clip

and tighten.  Cut off excess strength member.

10.00 INSTALL ORGANIZER ASSEMBLY

10.01

Remove the torque bar attachment bolt from
the End Plate and secure the Buffer Tube

Storage and Splice Tray Rack Torque Bar to the End
Plate. (Figure 20)

FIGURE 20 - BUFFER TUBE STORAGE AND

SPLICE TRAY RACK ASSEMBLY SECURED TO

END PLATES

11.00 ROUTE BUFFER TUBES TO

SPLICE TRAYS

11.01

Route buffer tubes as follows:

— Buffer tubes for the back nine splice trays are to
be routed beneath the Splice Tray Rack Assembly
through the buffer tube storage clips as shown in
Figure 21.

— Buffer tubes for the front nine splice trays are to
be routed above the Splice Tray Rack Assembly
through the upper buffer tube storage clips as shown
in Figure 22.

FIGURE 21 - ROUTING OF BUFFER TUBES FOR

BACK SPLICE TRAYS

Содержание Coyote HiCount

Страница 1: ...ES FOR FIELD DRILLED END PLATES 5 6 8 END PLATE ASSEMBLY 6 7 9 BONDING AND OR GROUNDING CABLES WITH METALLIC COMPONENTS 7 CONTENTS PAGE Be sure to read and completely understand this procedure before...

Страница 2: ...s Common screwdriver 1 2 deep well socket 3 8 nutdriver or socket Needlenose pliers Buffer tube removal tool and or slitter Sidecutters Torque Wrench inch pound readings Power End Plate Cutter Availab...

Страница 3: ...easure each cable at the area where the End Plate is to be placed 4 00 END PLATE PREPARATION CUTTER SET UP 4 01 When using blades A D install the blade directly into the chuck For blades E DD first in...

Страница 4: ...ck shaft PLP TIP A special drill motor is available from Preformed Line Products No matter what type of electric drill you use be sure to press down on the body of the drill so that pressure is not ex...

Страница 5: ...m a LOCK TAPE Sealant strip to dry and remove excess C Cement applied to End Plate Figure 13 FIGURE 13 C CEMENT ON END PLATE 6 04 Without stretching apply LOCK TAPE Sealant over prepared surface of th...

Страница 6: ...END PLATE ASSEMBLY 8 01 Using the hex bolts provided fasten the L bracket and retaining clip to the End Plate 8 02 Before installing prepared cables into End Plate halves apply 1 4 6 35 mm wide bead...

Страница 7: ...et through the slot pro vided 9 03 If cable contains a strength member insert the strength member into the retainer clip and tighten Cut off excess strength member 10 00 INSTALL ORGANIZER ASSEMBLY 10...

Страница 8: ...MOVE SPLICE TRAY COVER 12 03 Position the back splice tray on the Splice Tray Rack and route the buffer tubes into the LEFT corner of the splice tray Mark the buffer tubes just beyond the tie down hol...

Страница 9: ...ERS FROM THE FIELD BUFFER 12 09 Splice fibers according to accepted company practices tray Insert the tail into the head Press head down to the tray and hold in place while pulling the tail to tighten...

Страница 10: ...First Then Finally Hand Tighten in Sequence with Ratchet All 1 Bolts First Followed by all 2 Bolts and so on Torque Each Bolt Following the Sequence to 125 in lbs 14 N m 90 in lbs 10 N m for 4 Closur...

Страница 11: ...and grounding harness of the manhole Securely tighten all connections 16 03 For direct buried installations extend a length of bonding ribbon not supplied from one of the threaded inserts to a ground...

Страница 12: ...uct is intended for use by trained craftspeople only This product SHOULD NOT BE USED by anyone who is not familiar with and trained in the use of it 18 04 When working in the area of energized lines w...