background image

1. Lock Screw
2. 3.5” SATA Mobile Tray
  2-1. Drive 1
  2-2. Drive 2
3. Device LED
  3-1. Drive 1
  3-2. Drive 2
4. Power LED (Green)
5. Alarm LED (Red) 

6. AC Input 
    AC 100~240V, 47~63Hz, 72W
7. Power On/OFF
8. Cooling Fan
9. eSATA Connector
10. Host Status LEDs
11. Change Mode Button

12. Rotary switch
13. USB Host LED
14. USB B Type Connector
15. Alarm LED
16. Power LED

2

.

Installation Guide

T1-US2DS01

Overview

Introduction

6

9 10

11 12

13 14

15

16

7

8

1

2-1

3-1

4 5

2-2

3-2

Alarm LED:  (

Red LED)

Volume degradation (RAID 1) or unavailability 
(JBOD, Big, Fast) will be marked by turning on the 
Alarm LED and the alarm Buzzer for the node that 
experienced this behavior.

Power LED: (

Green LED)

LEDs on JBOD Mode
Description

Device Unplugged/No power
Device Plugged (Idle)
Device Plugged (Activity)

LEDs on RAID Mode
Description

Device Unplugged/No power
Device Plugged (Idle)
Device Plugged (Activity)
Disk Rebuild 
(A Physical Partition is being 
Rebuilt;Safe Mode(RAID 1))                  
Disk Rebuild-Verify 
(A Physical Partition is being                            
Verified; Safe Mode (RAID1))                                             

Green(Link)

Off
On
On

Link

Blink

On
On

Blink

On

Red(ACT)

Off
Off

Flash (On)

ACT

Blink

Off

Flash (On)

On

Flash (On)

will appear as On

Device LED (ACT & Link) :

Normal

LED

RAID 1 Status

Error

ON

OFF

You can configure the T1-US2DS01 to use the following Storage 
Policies to map its appliance's physical hard drives to virtual drives 
that are visible to the host computer. 

- BIG (Concatenation)
- JBOD (Just a Bunch Of Disks)
- FAST (RAID 0)
- SAFE (RAID 1)
- SAFE33 (1/3 to SAFE mode and 2/3 to BIG mode)
- SAFE50 (1/2 to SAFE mode and 1/2 to BIG mode)
- GUI (Use the SteelVine Manager GUI to configure the Storage Policy)

Rotary switch:

To select a storage policy in this mode the first time that 
a new factory-shipped product is used, ensure that the 
hard disk drives are installed, set the rotary switch on 
the back of the T1-US2DS01 to the desired Storage 
Policy (not the GUI selection) and turn on the power. 

Change Mode Button:

To change the storage policy thereafter, set the rotary 
switch to the desired position and press the recessed 
Change Mode Button to create the new virtual 
volume(s). Creating new virtual volumes will destroy 
any existing data that existed on the previous volume, 
but expanding an existing BIG volume will not destroy 
any existing data.

LEDs

Front Panel

Back Panel

Rotary switch & Change Mode Button

DISK 1

DISK 2

Activity

(Red)

Link

(Green)

Activity

(Red)

Link

(Green)

T1-US2DS01 is an eSATA & USB 2.0 Combo to Dual SATA RAID storage enclosure.
It provides two hot-swappable 3.5" HDD mobile trays for easy installation and un-installation.
T1-US2DS01 is a hardware RAID enclosure, requiring no software installation on the user’s machine. 
The user can select different RAID modes for the two 3.5" SATA HDDs. 

You can configure the T1-US2DS01 to use the following Storage Policies to map its appliance's physical hard drives to virtual drives that are visible to 
the host computer.
    * BIG (Concatenation)
    * JBOD (Just a Bunch Of Disks)
    * FAST (RAID 0)
    * SAFE (RAID 1)
    * SAFE33 (1/3 to SAFE mode and 2/3 to BIG mode)
    * SAFE50 (1/2 to SAFE mode and 1/2 to BIG mode)
    * GUI (Use the SteelVine Manager GUI to configure the Storage Policy)

QL.NB278.12