background image

5

Step #6a If using cut cable, insert cable 

through grommet. If your application 
requires express/balloon/ring cut 
cables, 

see Step 7 for grommet 

slitting procedure.

Install plug in 
unused port

Diameter 
range 
top hole

Diameter 
range bottom 
hole

Step #5 Measure cable to determine diameter 

and hole location to use in grommet.

Step #6b Installing Figure 8 Style Cables and 

Cables with Tracer Wires – Remove 
tracer wire or ground wire from the por-
tion of the cable that will be positioned 
in the grommet and insert the cable into 
the grommet

.

Cable with  

Tracer Wire

Figure 8  

Style Cable

Not Correct  

Installation

Correct  

Installation

Not Correct  

Installation

Correct  

Installation

Step #7 Grommet Slitting – If slitting is  

required, lay grommet on a stable flat 
surface. Position utility knife with the 
cutting edge against the top surface and 
cut through grommet.
Consult grommet chart on page 3 for 
slitting locations of all grommets.

PLP Tip: Use a pen to sketch slitting lines on top 

surface of grommet prior to cutting.

Not Correct  

Slitting Angle

Correct  

Slitting Angle

Slit

Slit

Step #8a Trim strength members to length.

Prepare feeder and local cable(s) for 
cut applications.

Minimum Sheath Opening for  

Cut Cable Applications

77"

2.0 m

Buffer (Loose)  

Tube Cable

2.5" (6.4 cm)

Strength Member

Step #8b Prepare cable(s) for mid sheath appli-

cations. (Express/Balloon/Ring Cut).

For Applications Where Fiber is  

Dedicated to the Splice Point

Sheath Opening

77" (2.0 m)

Fiber/Buffer Tube  

Cut Location

A (see image above)

Buffer (Loose)  

Tube Cable

A

X

 77" (2.0 m)

OFFICE/C

.O.

Содержание 800012184

Страница 1: ...escription 800012185 COYOTE Dome Cross Connect Closure 6 5 x 17 Includes 2 Grommets 1 Cross Connect Organizer Assembly with 4 Port End Plate Assembly 1 Dome 1 Collar Assembly 1 Gasket 8 Plastic Organi...

Страница 2: ...r Coded SC SM 3 meter P12FC3 12 Simplex 900 Micron Color Coded FC SM 3 meter P6SCA3 6 Simplex 900 Micron Color Coded SC SM APC 3 meter P12FC5 12 Simplex 900 Micron Color Coded FC SM 5 meter P12SCA3 12...

Страница 3: ...met 8003694 1 0 1 25 25 32 mm 1 entry grommet 8003663 42 60 11 15 mm 2 entry grommet 8003990 50 60 12 7 15 2 125 25 3 2 6 4 and flat drop 4 entry grommet 8003664 30 43 8 11 mm 4 entry grommet 8004065...

Страница 4: ...ase Position sup port bracket onto base and secure with wing nuts Note Do not tighten wing nut until end plate is installed Base can be secured to work surface with either clamps or with bolts Loosen...

Страница 5: ...on Step 7 Grommet Slitting If slitting is required lay grommet on a stable flat surface Position utility knife with the cutting edge against the top surface and cut through grommet Consult grommet cha...

Страница 6: ...icate seal ing surface of grommet with silicone lubri cant provided Step 10b Position grommet in end plate slot For Wide Range 2 Hole Grommets make sure arrows are pointing down when inserting grommet...

Страница 7: ...th hose clamp PLP Tip Avoid contact between hose clamp and shield connector to maintain isolation of each cable ground Organizer Preparation Step 16 Attach bonding device between the cable and ground...

Страница 8: ...cm Step 21a Step 20 Select feeder fiber to be spliced Route and store buffer tubes in storage brackets X Cut fiber to be spliced here Cut fiber Secure adapter plate assembly to mainframe with fastener...

Страница 9: ...te and press into groove Make sure gasket is seated in groove of end plate Step 30 Re tighten all cable cap bolts step 11 to assure that the cable caps are fully seated When using a can wrench or nut...

Страница 10: ...e collar in place push against the end of the dome and slightly lift and push the other half of the dome up and over the lip of the collar with your fingers to fully install the dome in the collar hal...

Страница 11: ...end plate Step 40 Pressurize closure up to a max of 10 psi Step 42 Release the pressure in the closure using the bump on the top of the air valve cap Step 41 Spray all sealing surfaces of the dome en...

Страница 12: ...the corner of the cable port Leak occurring at the cable entry of the grommet due to the cable not being within the stated cable diameter range of the grommet To resolve remove collar and remove End P...

Страница 13: ...cket with the bolts and keps nuts provided For 6 5 Dome Strand Mount Aerial Offset Bracket Kit P N 8004035 and 6 5 Dome ADSS Mount Aerial Offset Bracket Kit P N 8004036 Step 43c Position 1 Strand Clam...

Страница 14: ...and hole using 2 screws Step 48 COYOTE Universal Mounting Bracket for Hand Hole Applications P N 8003835 Insert banding plastic or metal through the slots of the hanger brackets COYOTE Universal Mount...

Страница 15: ...lates are secure Stud Mount Plate 1 8 3mm Stud Mount Plate Pole Wall Mount Bracket Secure Lock Nuts The 6 5 COYOTE Dome Pole Wall Mount Bracket P N 8003702 Step 54 Attach the COYOTE Dome closure to th...

Страница 16: ...red trademark of the DuPont Company Step 55b The COYOTE Dome Mount Aerial Bracket Kit for ADSS Cat No 8003833 can be used to suspend the COYOTE 6 5 x 17 or 6 5 x 22 Dome Closure from ADSS cable To ins...