12
Common End Plate Leaks During
Flash Testing
Leak occurring at the corner of the cable
port due to the cap of the cable port not
being fully tightened.
To resolve, remove collar, remove End Plate/
Organizer Assembly from the Dome, and
tighten bolts on end cap where leak occurred.
Reassemble and flash test to confirm that the
leak has stopped.
Leak occurring at the
corner of the cable port
Leak occurring at the cable entry of the
grommet due to the cable not being within the
stated cable diameter range of the grommet
To resolve, remove collar and remove End
Plate/Organizer Assembly from the Dome.
Remove end cap where leak occurred, remove
grommet, remeasure cable with measure
tape provided and select proper grommet.
Reassemble the components and flash test the
closure to confirm that the leak has stopped.
Leak occurring at the cable
entry of the grommet