40108 

RO 

UINT32 

 

CH 1 Totalizer Count 

40110

 

RO

 

FLOAT

 

 

CH 2 Process Variable

 

40112

 

RO

 

FLOAT

 

 

CH 2 Alarm 1 Setpoint

 

40114

 

RO

 

UINT8

 

Enumeration

 

CH 2 Alarm 1 Type: 

0=Disabled, 1=LoLo, 2=Lo, 3=Hi, 4=HiHi 

40115

 

RO

 

FLOAT

 

 

CH 2 Alarm 2 Setpoint

 

40117

 

RO

 

UINT8

 

Enumeration

 

CH 2 Alarm 2 Type: 

0=Disabled, 1=LoLo, 2=Lo, 3=Hi, 4=HiHi 

40118

 

RO

 

UINT32

 

 

CH 2 Totalizer Count

 

40120

 

RO

 

FLOAT

 

 

CH 3 Process Variable

 

40122

 

RO

 

FLOAT

 

 

CH 3 Alarm 1 Setpoint

 

40124

 

RO

 

UINT8

 

Enumeration

 

CH 3 Alarm 1 Type: 

0=Disabled, 1=LoLo, 2=Lo, 3=Hi, 4=HiHi 

40125

 

RO

 

FLOAT

 

 

CH 3 Alarm 2 Setpoint

 

40127

 

RO

 

UINT8

 

Enumeration

 

CH 3 Alarm 2 Type: 

0=Disabled, 1=LoLo, 2=Lo, 3=Hi, 4=HiHi 

40128

 

RO

 

UINT32

 

 

CH 3 Totalizer Count

 

 
 

 

 

Содержание JC-13D2

Страница 1: ...sensor Units totalizer Units 50 pt Alarm Event History Time Date Stamped Only 4 7 8 deep fits in most existing burner control cabinets Plug in field wiring terminals Modbus TCP Ethernet Modbus RTU RS...

Страница 2: ...ntinuously indicate the AIN Process Variable PV value The alarm setpoints are indicated on the bargraph with tic marks If the PV exceeds a Hi or HiHi Setpoint for more than 30 seconds adjustable the b...

Страница 3: ...ms Alarms will not be displayed on the Main and Menu screens All active Alarms are displayed on this screen High Alarm High High Alarm etc The PV and time date shown occurred when the Alarm time delay...

Страница 4: ...elds only where shown insulate all other shields to prevent accidental grounding Ignition transformer and motor VFD wiring are particularly electrically noisy and should be kept away from the thermoco...

Страница 5: ...ts 45 47 49 RS485 RS485 Common Ethernet 43 24 Vdc 7 ACDIN 1 8 ACDIN 2 37 24V 32 2 5Vref 38 AIN 3 39 DC 44 DCDIN 1 46 DCDIN 2 DC 24 Vdc 120 Vac 1 2 3 Relay 1 6 5 4 Relay 2 Channel 3 35 24V 32 2 5Vref 3...

Страница 6: ...r Fuse JC 10D2 31 34 33 A D 2 Wire 4 20 mA Xmtr INPUT TYPE mA Thermistor Fuse 24V JC 10D2 Thermocouple and Thermistor Field Wiring Notes Do not run in conduits with AC wiring Do not run in conduits wi...

Страница 7: ...nction DC DIN 2 Function Discrete Outputs ROUT 1 Function ROUT 2 Function DOUT 1 Function DOUT 2 Function 4 20 mA Outputs AOUT 0 1 Channel AOUT 0 1 4 mA AOUT 0 1 20 mA AOUT 0 2 Channel AOUT 0 2 4 mA A...

Страница 8: ...ow Cutoff Alarm 1 2 Types Alarm 1 Type Alarm 1 Reset Type Alarm 2 Type Alarm 2 Reset Type Bargraph Setup Tick Decimal Places Bargraph Top Bargraph Bottom Analog Input Setup Input Name Input Type Smoot...

Страница 9: ...t Types 6 0 0 15 0 15 0 Temperature Adjust degrees The displayed value is offset from the measured value by this amount for all temperatures Used to calibrate out minor temperature differences due to...

Страница 10: ...ion Totalized values can be reset to zero when User presses this button 28 Hour Day Minute Rate Time Base Minute Hour Day Examples gpm use Minute gph use Hour gal day use Day 29 x1 x1000000 x1 Rate Mu...

Страница 11: ...ed AIN Error Disabled DOUT 2 Function Disabled Alarm 1 Alarm 2 Common Alarm Horn AIN Error NOTE Horn is Off after Alarm s are silenced AIN Error means mA Vdc Out of Range T C Open Thermistor Shorted o...

Страница 12: ...H 2 Alarm 2 Setpoint 40117 RO UINT8 Enumeration CH 2 Alarm 2 Type 0 Disabled 1 LoLo 2 Lo 3 Hi 4 HiHi 40118 RO UINT32 CH 2 Totalizer Count 40120 RO FLOAT CH 3 Process Variable 40122 RO FLOAT CH 3 Alarm...

Страница 13: ...EL D4B Adapter Plate Panel Cutout 8 00 X 10 75 Specifications Mechanical Enclosure Nema 12 Faceplate Indoor Locations Bezel 3 7 8 w x 8 h x 1 d Rear Case 3 1 2 w x 7 9 16 h x 4 7 8 d Panel Cutout 3 6...

Страница 14: ...SDI JC 13D2 rev 8 22 22 page 14 of 14 Preferred Utilities Mfg Corp Preferred Instruments div 31 35 South Street Danbury CT 06810 203 743 6741 www preferred mfg com...