ADG-L Series Programmable DC Power Supply
43
3.3.1
Constant voltage (CV) mode setting
Press the item VOLTAGE at the MAIN page to enter into the setting page of constant
voltage (CV) mode (refer to Figure 3.6). The voltage range varies according to the
models (refer to Section1.3). Below is an example of model ADG-L-335-135-15, of
which the output voltage ranges from 0.0V~ 342.0V. The product’s factory default
maxi-mum set voltage is approximately 102% (342.0 = 335V * 1.02) of the maximum
rated output voltage.
Figure 3.6 CV mode setting in MAIN page
Notice
When output in CV mode, set current value in in the meantime to make sure
outpur correctly. For more information, please refer to section 3.3.2
3.3.2
Constant current (CC) mode setting
Press the item CURRENT at the MAIN page to enter into the setting page of constant
current (CC) mode (refer to Figure 3.7). The current range varies according to the
models (refer to section 1.3). Below is an example of model ADG-L-335-135-15, of
which the output current ranges from 0.00A ~ 137.83A. The product’s factory default
maximum set current is approximately 102% (137.7A = 135A * 1.02) of the maximum
rated output current. The CC mode is only active when the output current is larger or
equal to the set value of CC; the device will then adjust the output voltage to main-
tain the output current as the set value of CC.
Содержание ADG-L Series
Страница 24: ...ADG L Series Programmable DC Power Supply 16 Figure 2 1 The required space for the device...
Страница 77: ...ADG L Series Programmable DC Power Supply 69 Figure 3 32 Ethernet setting Figure 3 33 RS 232 RS 485 USB setting...
Страница 98: ...ADG L Series Programmable DC Power Supply 90 Figure 4 10 Export report CSV and TXT format...
Страница 127: ...ADG L Series Programmable DC Power Supply 119 Figure 6 9 Process to output reading voltage and setting voltage...
Страница 133: ...ADG L Series Programmable DC Power Supply 125 Figure 6 19 Current indicated value and set value calibration page...
Страница 135: ...ADG L Series Programmable DC Power Supply 127 Figure 6 22 Output power calibration page...